★ OpsStar

Oakwood Gardens Care Center: Survey Readiness Report

3510 East Shields, Fresno, CA 93726 · CCN 055204 · 103 beds · CMS 4★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jul 2, 2026 · 4 months ago · previous Jan 30, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Medication use (F759)
    F759 cited in 3 of the last 3 inspection cycles
  2. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  3. Staffing levels and RN coverage (F725)
    4 staffing measures below the state average; Nursing turnover 53.4% vs 36.6% state average
  4. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  5. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F759
3 of 3 cycles
Ensure medication error rates are not 5 percent or greater.
Worst: E · last cited Jul 2, 2026
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jul 2, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: F · last cited Jul 2, 2026
F658
2 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: E · last cited Jul 2, 2026
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Jul 2, 2026
F911
2 of 3 cycles
Ensure resident rooms hold no more than 4 residents; for new construction after November 28, 2016, rooms hold no more…
Worst: D · last cited Jan 30, 2025

34 health citations across 27 different tags in the last 3 cycles. Last standard survey: 15 citations (California average 15.7).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months2
Complaint citations, last 3 cycles7
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeCaliforniaU.S.
Total nurse hours per resident per day4.084.543.90
Weekend nurse hours per resident per day3.694.103.43
RN hours per resident per day0.360.680.69
Weekend RN hours per resident per day0.320.520.48
Nursing staff turnover53.4%36.6%45.3%
RN turnover14.3%37.8%42.5%
Administrators who left (past year)n/a0.40.5

Weekend nurse staffing is 10% below weekdays (10% statewide). CMS expects about 4.01 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeCaliforniaU.S.
Falls with major injury (long-stay)
F689
2.6%1.6%3.2%
Pressure ulcers (long-stay)
F686
1.7%4.3%4.5%
Antipsychotic medication (long-stay)
F758
3.8%12.3%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.3%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
6.8%13.7%19.5%
Urinary tract infections (long-stay)
F690
0.0%1.2%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.7%0.7%
New or worse incontinence (long-stay)
F690
14.0%9.8%18.3%
Losing too much weight (long-stay)
F692
4.7%4.1%5.1%
Needing more help with daily activities (long-stay)
F676
6.6%10.2%13.5%
Walking ability got worse (long-stay)
F676
5.9%8.9%12.7%
Depressive symptoms (long-stay)
F740
4.5%7.6%13.5%
Physically restrained (long-stay)
F604
0.0%0.3%0.1%
Sent back to the hospital (short-stay)
F660
27.2%22.6%23.4%
ER visits (short-stay)
F684
9.5%11.1%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.632.211.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey11 (California average 6.3)
Repeat fire safety tagsK345 (2 cycles), K920 (3 cycles), K353 (3 cycles), K363 (2 cycles), K919 (3 cycles), E039 (2 cycles), K347 (2 cycles), K918 (2 cycles)
Fire safety citations on the last survey
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K920
E
Ensure proper usage of power strips and extension cords.
K353
D
Inspect, test, and maintain automatic sprinkler systems.
K363
D
Install corridor and hallway doors that block smoke.
K919
D
Meet requirements for the use of electrical equipment.
E004
C
Develop and maintain an Emergency Preparedness Program (EP).
E013
C
Develop Emergency Preparedness policies and procedures.
E029
C
Develop a communication plan.
E036
C
Establish emergency prep training and testing.
E039
C
Conduct testing and exercise requirements.
K712
C
Have simulated fire drills held at unexpected times.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.