John C. Fremont Healthcare District Dp/SNF: Survey Readiness Report

5189 Hospital Road, Mariposa, CA 95338 · CCN 055283 · 16 beds · CMS 2★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Feb 10, 2026 · 9 months ago · previous Aug 8, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Staffing levels and RN coverage (F727, F725)
    F727 cited in 2 of the last 3 inspection cycles; 1 staffing measure below the state average; Weekend staffing drops 22% vs 10% statewide
  2. Daily living care (ADLs) (F676)
    Needing more help with daily activities (long-stay): 22.0% vs 10.2% state average; Walking ability got worse (long-stay): 24.0% vs 8.9% state average
  3. Quality of care (F658)
    F658 cited in 2 of the last 3 inspection cycles
  4. Care plans (F656)
    F656 cited in 2 of the last 3 inspection cycles
  5. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F727
2 of 3 cycles
Have a registered nurse on duty 8 hours a day; and select a registered nurse to be the director of nurses on a full…
Worst: F · last cited Aug 8, 2024
F658
2 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: E · last cited Feb 10, 2026
F656
2 of 3 cycles
Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can…
Worst: E · last cited Feb 10, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: D · last cited Feb 10, 2026

15 health citations across 11 different tags in the last 3 cycles. Last standard survey: 10 citations (California average 15.7).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles0
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeCaliforniaU.S.
Total nurse hours per resident per day6.614.543.90
Weekend nurse hours per resident per day5.164.103.43
RN hours per resident per day0.850.680.69
Weekend RN hours per resident per day0.200.520.48
Nursing staff turnover18.2%36.6%45.3%
RN turnovern/a37.8%42.5%
Administrators who left (past year)n/a0.40.5

Weekend nurse staffing is 22% below weekdays (10% statewide). CMS expects about 3.47 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeCaliforniaU.S.
Falls with major injury (long-stay)
F689
3.3%1.6%3.2%
Pressure ulcers (long-stay)
F686
1.4%4.3%4.5%
Antipsychotic medication (long-stay)
F758
28.8%12.3%15.4%
Anti-anxiety or sleep medication (long-stay)
F758
3.3%13.7%19.5%
Urinary tract infections (long-stay)
F690
1.6%1.2%1.5%
Catheter left in bladder (long-stay)
F690
1.5%0.7%0.7%
New or worse incontinence (long-stay)
F690
36.5%9.8%18.3%
Losing too much weight (long-stay)
F692
0.0%4.1%5.1%
Needing more help with daily activities (long-stay)
F676
22.0%10.2%13.5%
Walking ability got worse (long-stay)
F676
24.0%8.9%12.7%
Depressive symptoms (long-stay)
F740
5.4%7.6%13.5%
Physically restrained (long-stay)
F604
0.0%0.3%0.1%

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey9 (California average 6.3)
Repeat fire safety tagsK345 (2 cycles), K355 (3 cycles), K363 (2 cycles), K161 (2 cycles), K321 (2 cycles)
Fire safety citations on the last survey
E037
F
Establish staff and initial training requirements.
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K926
F
Ensure that personnel concerned with handling of medical gases and cylinders are trained on the…
K342
D
Have a complete alarm system manually initiated and initiated by fire sprinkler system connection.
K355
D
Properly select, install, inspect, or maintain portable fire extinguishes.
K363
D
Install corridor and hallway doors that block smoke.
K923
D
Have proper medical gas storage and administration areas.
K712
C
Have simulated fire drills held at unexpected times.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.