★ OpsStar

Cornerstone Care Center: Survey Readiness Report

2550 9th Street, Sanger, CA 93657 · CCN 056100 · 99 beds · CMS 3★ overall

Past the 15-month federal limit: a survey could come any day
Last standard survey May 1, 2025 · 18 months ago · previous Jun 10, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Medication use (F757, F759, F755)
    F757 cited in 3 of the last 3 inspection cycles; F759 cited in 2 of the last 3 inspection cycles; F755 cited in 2 of the last 3 inspection cycles
  2. Psychotropic medications (F758)
    F758 cited in 2 of the last 3 inspection cycles; F758 cited at harm level G (Jun 10, 2024); F758 cited at harm level H (Feb 15, 2022)
  3. Quality of care (F658, F685)
    F658 cited in 3 of the last 3 inspection cycles; F685 cited at harm level G (Jun 10, 2024)
  4. Infection prevention and control (F880)
    F880 cited in 3 of the last 3 inspection cycles; F880 cited 3 times in the last 3 cycles
  5. Staffing levels and RN coverage (F725)
    4 staffing measures below the state average; Weekend staffing drops 16% vs 10% statewide; Nursing turnover 50.0% vs 36.6% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F658
3 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: E · last cited May 1, 2025
F761
3 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: E · last cited May 1, 2025
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited May 1, 2025
F757
3 of 3 cycles
Ensure each resident’s drug regimen must be free from unnecessary drugs.
Worst: D · last cited May 1, 2025
F758
2 of 3 cycles
Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to…
Worst: H · last cited Jun 10, 2024
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited May 1, 2025
F550
2 of 3 cycles
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her…
Worst: E · last cited May 1, 2025
F759
2 of 3 cycles
Ensure medication error rates are not 5 percent or greater.
Worst: E · last cited May 1, 2025
F656
2 of 3 cycles
Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can…
Worst: E · last cited Jun 10, 2024
F755
2 of 3 cycles
Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed…
Worst: E · last cited Jun 10, 2024
F641
2 of 3 cycles
Ensure each resident receives an accurate assessment.
Worst: D · last cited May 1, 2025

52 health citations across 34 different tags in the last 3 cycles. Last standard survey: 16 citations (California average 15.7).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F758
G
Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to…
Actual harm · Jun 10, 2024
F685
G
Assist a resident in gaining access to vision and hearing services.
Actual harm · Jun 10, 2024
F697
G
Provide safe, appropriate pain management for a resident who requires such services.
Actual harm · Feb 15, 2022
F758
H
Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to…
Actual harm · Feb 15, 2022

Complaints and infection control

Complaint citations, past 12 months2
Complaint citations, last 3 cycles7
Infection control (F880) citations, last 3 cycles3

Staffing payroll-based journal (PBJ)

MeasureThis homeCaliforniaU.S.
Total nurse hours per resident per day3.884.543.90
Weekend nurse hours per resident per day3.274.103.43
RN hours per resident per day0.390.680.69
Weekend RN hours per resident per day0.310.520.48
Nursing staff turnover50.0%36.6%45.3%
RN turnover53.8%37.8%42.5%
Administrators who left (past year)2.00.40.5

Weekend nurse staffing is 16% below weekdays (10% statewide). CMS expects about 3.90 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeCaliforniaU.S.
Falls with major injury (long-stay)
F689
0.6%1.6%3.2%
Pressure ulcers (long-stay)
F686
3.1%4.3%4.5%
Antipsychotic medication (long-stay)
F758
5.2%12.3%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.3%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
18.1%13.7%19.5%
Urinary tract infections (long-stay)
F690
0.7%1.2%1.5%
Catheter left in bladder (long-stay)
F690
1.0%0.7%0.7%
New or worse incontinence (long-stay)
F690
5.0%9.8%18.3%
Losing too much weight (long-stay)
F692
2.2%4.1%5.1%
Needing more help with daily activities (long-stay)
F676
11.1%10.2%13.5%
Walking ability got worse (long-stay)
F676
13.7%8.9%12.7%
Depressive symptoms (long-stay)
F740
3.9%7.6%13.5%
Physically restrained (long-stay)
F604
0.0%0.3%0.1%
Sent back to the hospital (short-stay)
F660
22.1%22.6%23.4%
ER visits (short-stay)
F684
15.8%11.1%11.8%
Hospitalizations per 1,000 long-stay days
F684
2.102.211.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $27,612
Payment denials, past 3 yearsNone
Fire safety citations, last survey10 (California average 6.3)
Repeat fire safety tagsK918 (2 cycles), K919 (3 cycles), K711 (2 cycles), K920 (2 cycles), K923 (2 cycles), K355 (2 cycles), K363 (2 cycles)
Fire safety citations on the last survey
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K919
E
Meet requirements for the use of electrical equipment.
K222
D
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K324
D
Provide properly protected cooking facilities.
K353
D
Inspect, test, and maintain automatic sprinkler systems.
K711
D
Provide a written emergency evacuation plan.
K920
D
Ensure proper usage of power strips and extension cords.
K923
D
Have proper medical gas storage and administration areas.
E041
C
Implement emergency and standby power systems.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.