★ OpsStar

Denver North Care Center: Survey Readiness Report

2201 N Downing St, Denver, CO 80205 · CCN 065323 · 82 beds · CMS 4★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Dec 18, 2025 · 11 months ago · previous Jan 9, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Psychotropic medications (F758)
    F758 cited in 2 of the last 3 inspection cycles; Antipsychotic medication (long-stay): 30.6% vs 19.9% state average
  2. Food safety and kitchen (F812)
    F812 cited in 3 of the last 3 inspection cycles
  3. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  4. Daily living care (ADLs) (F676)
    F676 cited in 2 of the last 3 inspection cycles
  5. Staffing levels and RN coverage (F725)
    4 staffing measures below the state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
3 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Dec 18, 2025
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Dec 18, 2025
F758
2 of 3 cycles
Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to…
Worst: E · last cited Jan 9, 2024
F676
2 of 3 cycles
Ensure residents do not lose the ability to perform activities of daily living unless there is a medical reason.
Worst: D · last cited Jan 9, 2024

33 health citations across 28 different tags in the last 3 cycles. Last standard survey: 10 citations (Colorado average 8.7).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles5
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeColoradoU.S.
Total nurse hours per resident per day2.803.693.90
Weekend nurse hours per resident per day2.493.263.43
RN hours per resident per day0.430.810.69
Weekend RN hours per resident per day0.330.600.48
Nursing staff turnover26.4%47.0%45.3%
RN turnover20.0%44.4%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 11% below weekdays (12% statewide). CMS expects about 3.03 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeColoradoU.S.
Falls with major injury (long-stay)
F689
3.5%3.4%3.2%
Pressure ulcers (long-stay)
F686
1.1%3.4%4.5%
Antipsychotic medication (long-stay)
F758
30.6%19.9%15.4%
Anti-anxiety or sleep medication (long-stay)
F758
10.4%11.6%19.5%
Urinary tract infections (long-stay)
F690
1.0%1.4%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.5%0.7%
New or worse incontinence (long-stay)
F690
9.2%20.6%18.3%
Losing too much weight (long-stay)
F692
6.4%4.8%5.1%
Needing more help with daily activities (long-stay)
F676
5.2%12.8%13.5%
Walking ability got worse (long-stay)
F676
4.4%11.7%12.7%
Depressive symptoms (long-stay)
F740
10.5%8.8%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey8 (Colorado average 5.9)
Repeat fire safety tagsK353 (3 cycles), K363 (2 cycles)
Fire safety citations on the last survey
K291
F
Install emergency lighting that can last at least 1 1/2 hours.
K293
F
Have properly located and lighted "Exit" signs.
K324
F
Provide properly protected cooking facilities.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K541
F
Install properly constructed and protected linen or trash chutes.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K927
F
Have proper fire barriers, ventilation and signs for the transfilling of oxygen.
K321
D
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.