★ OpsStar

Life Care Center of Aurora: Survey Readiness Report

14101 E Evans Ave, Aurora, CO 80014 · CCN 065332 · 166 beds · CMS 5★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Apr 9, 2026 · 7 months ago · previous Feb 27, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; F689 cited at harm level G (Feb 27, 2024); F689 cited at harm level G (Dec 1, 2022)
  2. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  3. Respiratory care (F695)
    F695 cited in 2 of the last 3 inspection cycles
  4. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles
  5. Hospital readmissions and discharge planning (F660)
    Sent back to the hospital (short-stay): 27.6% vs 20.5% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: G · last cited Feb 27, 2024
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited Apr 9, 2026
F695
2 of 3 cycles
Provide safe and appropriate respiratory care for a resident when needed.
Worst: D · last cited Apr 9, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: D · last cited Apr 9, 2026

24 health citations across 20 different tags in the last 3 cycles. Last standard survey: 7 citations (Colorado average 8.7).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Feb 27, 2024
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Dec 1, 2022

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles2
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeColoradoU.S.
Total nurse hours per resident per day3.993.693.90
Weekend nurse hours per resident per day3.503.263.43
RN hours per resident per day1.080.810.69
Weekend RN hours per resident per day0.680.600.48
Nursing staff turnover26.5%47.0%45.3%
RN turnover22.2%44.4%42.5%
Administrators who left (past year)1.00.50.5

Weekend nurse staffing is 12% below weekdays (12% statewide). CMS expects about 3.83 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeColoradoU.S.
Falls with major injury (long-stay)
F689
1.9%3.4%3.2%
Pressure ulcers (long-stay)
F686
2.9%3.4%4.5%
Antipsychotic medication (long-stay)
F758
10.7%19.9%15.4%
New antipsychotic medication (short-stay)
F758
0.8%1.6%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
4.8%11.6%19.5%
Urinary tract infections (long-stay)
F690
0.5%1.4%1.5%
Catheter left in bladder (long-stay)
F690
0.2%0.5%0.7%
New or worse incontinence (long-stay)
F690
18.5%20.6%18.3%
Losing too much weight (long-stay)
F692
4.7%4.8%5.1%
Needing more help with daily activities (long-stay)
F676
4.7%12.8%13.5%
Walking ability got worse (long-stay)
F676
7.5%11.7%12.7%
Depressive symptoms (long-stay)
F740
5.9%8.8%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
27.6%20.5%23.4%
ER visits (short-stay)
F684
7.0%12.0%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.261.381.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $33,222
Payment denials, past 3 yearsNone
Fire safety citations, last survey19 (Colorado average 5.9)
Repeat fire safety tagsK324 (2 cycles), K345 (2 cycles), K353 (3 cycles)
Fire safety citations on the last survey
E001
F
Establish an Emergency Preparedness Program (EP).
K161
F
Use approved construction type or materials.
K222
F
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K291
F
Install emergency lighting that can last at least 1 1/2 hours.
K293
F
Have properly located and lighted "Exit" signs.
K300
F
Meet other general requirements that are deficient.
K321
F
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K324
F
Provide properly protected cooking facilities.
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K355
F
Properly select, install, inspect, or maintain portable fire extinguishes.
K363
F
Install corridor and hallway doors that block smoke.
K531
F
Have elevators that firefighters can control in the event of a fire.
K902
F
Meet requirements for the installation and maintenance of medical gas and medical vacuum systems.
K912
F
Have power receptacles that are properly grounded.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K781
E
Have restrictions on the use of portable space heaters.
K920
E
Ensure proper usage of power strips and extension cords.
K927
E
Have proper fire barriers, ventilation and signs for the transfilling of oxygen.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.