★ OpsStar

Advanced Health Care of Colorado Springs: Survey Readiness Report

55 S Parkside Dr, Colorado Springs, CO 80910 · CCN 065407 · 34 beds · CMS 5★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jun 25, 2026 · 5 months ago · previous Aug 15, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Staffing levels and RN coverage (F725)
    Weekend staffing drops 23% vs 12% statewide; Nursing turnover 60.4% vs 47.0% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

None. No tag was cited in more than one inspection cycle.

2 health citations across 2 different tags in the last 3 cycles. Last standard survey: 0 citations (Colorado average 8.7).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles0
Infection control (F880) citations, last 3 cycles0

Staffing payroll-based journal (PBJ)

MeasureThis homeColoradoU.S.
Total nurse hours per resident per day5.763.693.90
Weekend nurse hours per resident per day4.453.263.43
RN hours per resident per day1.520.810.69
Weekend RN hours per resident per day1.000.600.48
Nursing staff turnover60.4%47.0%45.3%
RN turnover77.8%44.4%42.5%
Administrators who left (past year)1.00.50.5

Weekend nurse staffing is 23% below weekdays (12% statewide). CMS expects about 5.35 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeColoradoU.S.
New antipsychotic medication (short-stay)
F758
0.3%1.6%1.5%
Sent back to the hospital (short-stay)
F660
19.8%20.5%23.4%
ER visits (short-stay)
F684
10.9%12.0%11.8%

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey12 (Colorado average 5.9)
Repeat fire safety tagsK346 (2 cycles), K353 (3 cycles), K354 (2 cycles), K355 (2 cycles), K363 (2 cycles), K918 (2 cycles), K324 (2 cycles)
Fire safety citations on the last survey
K161
F
Use approved construction type or materials.
K222
F
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K346
F
Follow proper procedures when the fire alarm was out of service for more than 4 hours.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K354
F
Follow proper procedures when the automatic sprinkler systems was out of service for more than 10…
K355
F
Properly select, install, inspect, or maintain portable fire extinguishes.
K363
F
Install corridor and hallway doors that block smoke.
K521
F
Ensure heating and ventilation systems that have been properly installed according to the…
K741
F
Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where…
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K923
F
Have proper medical gas storage and administration areas.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.