★ OpsStar

Civita Care Center at Newington: Survey Readiness Report

240 Church St, Newington, CT 06111 · CCN 075286 · 180 beds · CMS 1★ overall

CMS abuse icon: cited for abuse in the past year or in each of the past 2 years.

In the survey window: likely within the next 3 months
Last standard survey Nov 12, 2025 · 12 months ago · previous Dec 12, 2023
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 3 of the last 3 inspection cycles; F689 cited at harm level G (Apr 17, 2026); F689 cited at harm level G (Feb 11, 2026)
  2. Quality of care (F684, F658)
    F684 cited in 2 of the last 3 inspection cycles; F658 cited in 2 of the last 3 inspection cycles; Complaint citation for F658 in the past 12 months
  3. Medication storage and labeling (F761)
    F761 cited in 3 of the last 3 inspection cycles
  4. Psychotropic medications (F758)
    Antipsychotic medication (long-stay): 23.9% vs 17.7% state average; New antipsychotic medication (short-stay): 7.4% vs 1.4% state average
  5. Medical records (F842)
    F842 cited in 2 of the last 3 inspection cycles; Complaint citation for F842 in the past 12 months

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F689
3 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: J · last cited Apr 17, 2026
F761
3 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: D · last cited Nov 12, 2025
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Dec 12, 2023
F684
2 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: E · last cited Aug 28, 2025
F584
2 of 3 cycles
Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to…
Worst: E · last cited Nov 12, 2025
F755
2 of 3 cycles
Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed…
Worst: E · last cited Nov 12, 2025
F803
2 of 3 cycles
Ensure menus must meet the nutritional needs of residents, be prepared in advance, be followed, be updated, be…
Worst: E · last cited Nov 12, 2025
F658
2 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: D · last cited Apr 17, 2026
F842
2 of 3 cycles
Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance…
Worst: D · last cited Feb 11, 2026
F686
2 of 3 cycles
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Worst: D · last cited Nov 12, 2025
F655
2 of 3 cycles
Create and put into place a plan for meeting the resident's most immediate needs within 48 hours of being admitted
Worst: D · last cited Aug 6, 2024

55 health citations across 33 different tags in the last 3 cycles. Last standard survey: 20 citations (Connecticut average 13.3).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Apr 17, 2026 · complaint
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Feb 11, 2026 · complaint
F689
J
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Immediate jeopardy · Dec 19, 2025 · complaint
F600
H
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Actual harm · Oct 31, 2024 · complaint
F697
G
Provide safe, appropriate pain management for a resident who requires such services.
Actual harm · Dec 12, 2023
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Sep 9, 2021

Complaints and infection control

Complaint citations, past 12 months6
Complaint citations, last 3 cycles25
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeConnecticutU.S.
Total nurse hours per resident per day3.383.903.90
Weekend nurse hours per resident per day3.093.483.43
RN hours per resident per day0.380.710.69
Weekend RN hours per resident per day0.220.460.48
Nursing staff turnover45.1%37.3%45.3%
RN turnover63.6%38.0%42.5%
Administrators who left (past year)6.00.50.5

Weekend nurse staffing is 9% below weekdays (11% statewide). CMS expects about 3.50 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeConnecticutU.S.
Falls with major injury (long-stay)
F689
4.1%3.6%3.2%
Pressure ulcers (long-stay)
F686
4.1%3.9%4.5%
Antipsychotic medication (long-stay)
F758
23.9%17.7%15.4%
New antipsychotic medication (short-stay)
F758
7.4%1.4%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
17.0%18.0%19.5%
Urinary tract infections (long-stay)
F690
0.6%1.4%1.5%
Catheter left in bladder (long-stay)
F690
0.8%0.7%0.7%
New or worse incontinence (long-stay)
F690
13.7%24.0%18.3%
Losing too much weight (long-stay)
F692
6.7%6.4%5.1%
Needing more help with daily activities (long-stay)
F676
19.3%17.7%13.5%
Walking ability got worse (long-stay)
F676
16.2%14.8%12.7%
Depressive symptoms (long-stay)
F740
39.7%25.0%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Sent back to the hospital (short-stay)
F660
24.6%23.5%23.4%
ER visits (short-stay)
F684
12.9%10.4%11.8%
Hospitalizations per 1,000 long-stay days
F684
0.911.931.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years4 totaling $103,446
Payment denials, past 3 yearsNone
Fire safety citations, last survey17 (Connecticut average 4.1)
Repeat fire safety tagsK211 (2 cycles), K345 (2 cycles), K712 (2 cycles)
Fire safety citations on the last survey
E037
D
Establish staff and initial training requirements.
K211
D
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K225
D
Have stairways and smokeproof enclosures used as exits that meet safety requirements.
K324
D
Provide properly protected cooking facilities.
K345
D
Have approved installation, maintenance and testing program for fire alarm systems.
K351
D
Install an approved automatic sprinkler system.
K353
D
Inspect, test, and maintain automatic sprinkler systems.
K355
D
Properly select, install, inspect, or maintain portable fire extinguishes.
K363
D
Install corridor and hallway doors that block smoke.
K711
D
Provide a written emergency evacuation plan.
K712
D
Have simulated fire drills held at unexpected times.
K753
D
Have restrictions on the use of highly flammable decorations.
K761
D
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
K918
D
Have generator or other power source capable of supplying service within 10 seconds.
K919
D
Meet requirements for the use of electrical equipment.
K920
D
Ensure proper usage of power strips and extension cords.
K921
D
Ensure that testing and maintenance of electrical equipment is performed.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.