★ OpsStar

Tybee Island Trails of Journey LLC: Survey Readiness Report

26 Van Horne Street, Tybee Island, GA 31328 · CCN 115633 · 50 beds · CMS 1★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Jan 30, 2026 · 9 months ago · previous Oct 28, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Staffing levels and RN coverage (F725)
    4 staffing measures below the state average; Weekend staffing drops 21% vs 13% statewide; Nursing turnover 77.8% vs 46.8% state average
  2. Food safety and kitchen (F812)
    F812 cited in 3 of the last 3 inspection cycles
  3. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  4. Abuse and neglect (F609)
    F609 cited in 2 of the last 3 inspection cycles; Complaint citation for F609 in the past 12 months
  5. Resident rights and dignity (F550)
    F550 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
3 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jan 30, 2026
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited Jan 30, 2026
F609
2 of 3 cycles
Timely report suspected abuse, neglect, or theft and report the results of the investigation to proper authorities.
Worst: D · last cited Jul 29, 2026
F550
2 of 3 cycles
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her…
Worst: D · last cited Jan 30, 2026

26 health citations across 21 different tags in the last 3 cycles. Last standard survey: 8 citations (Georgia average 4.9).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F697
G
Provide safe, appropriate pain management for a resident who requires such services.
Actual harm · Jan 30, 2026

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles12
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeGeorgiaU.S.
Total nurse hours per resident per day2.343.613.90
Weekend nurse hours per resident per day1.863.123.43
RN hours per resident per day0.420.500.69
Weekend RN hours per resident per day0.280.350.48
Nursing staff turnover77.8%46.8%45.3%
RN turnover80.0%46.1%42.5%
Administrators who left (past year)n/a0.60.5

Weekend nurse staffing is 21% below weekdays (13% statewide). CMS expects about 4.28 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeGeorgiaU.S.
Falls with major injury (long-stay)
F689
5.8%3.2%3.2%
Pressure ulcers (long-stay)
F686
7.8%5.4%4.5%
Antipsychotic medication (long-stay)
F758
52.5%19.8%15.4%
Anti-anxiety or sleep medication (long-stay)
F758
22.9%20.5%19.5%
Urinary tract infections (long-stay)
F690
1.7%2.4%1.5%
Catheter left in bladder (long-stay)
F690
0.5%0.8%0.7%
New or worse incontinence (long-stay)
F690
3.3%15.4%18.3%
Losing too much weight (long-stay)
F692
6.8%5.4%5.1%
Needing more help with daily activities (long-stay)
F676
15.8%14.9%13.5%
Walking ability got worse (long-stay)
F676
6.8%13.7%12.7%
Depressive symptoms (long-stay)
F740
73.9%11.7%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
18.2%24.4%23.4%
ER visits (short-stay)
F684
4.3%11.3%11.8%
Hospitalizations per 1,000 long-stay days
F684
2.592.071.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 years1
Fire safety citations, last survey5 (Georgia average 3.2)
Repeat fire safety tagsK321 (2 cycles), K293 (2 cycles), K353 (2 cycles)
Fire safety citations on the last survey
K321
E
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K222
D
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K232
D
Have corridors or aisles that are unobstructed and are at least 8 feet in width.
K291
D
Install emergency lighting that can last at least 1 1/2 hours.
K293
D
Have properly located and lighted "Exit" signs.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.