★ OpsStar

Bella Terra Streamwood: Survey Readiness Report

815 East Irving Park Road, Streamwood, IL 60107 · CCN 145701 · 214 beds · CMS 5★ overall

Past the 15-month federal limit: a survey could come any day
Last standard survey Mar 20, 2025 · 20 months ago · previous Apr 4, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; F689 cited at harm level G (Mar 20, 2025)
  2. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  3. Psychotropic medications (F758)
    New antipsychotic medication (short-stay): 5.7% vs 2.2% state average; Anti-anxiety or sleep medication (long-stay): 22.3% vs 18.4% state average
  4. Resident rights and dignity (F550)
    F550 cited in 2 of the last 3 inspection cycles; Complaint citation for F550 in the past 12 months
  5. Nutrition and weight loss (F692)
    Losing too much weight (long-stay): 12.4% vs 6.1% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: G · last cited Mar 20, 2025
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Apr 4, 2024
F550
2 of 3 cycles
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her…
Worst: D · last cited Dec 5, 2025

16 health citations across 13 different tags in the last 3 cycles. Last standard survey: 3 citations (Illinois average 12.7).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Mar 20, 2025 · complaint

Complaints and infection control

Complaint citations, past 12 months2
Complaint citations, last 3 cycles5
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeIllinoisU.S.
Total nurse hours per resident per day3.303.473.90
Weekend nurse hours per resident per day3.163.083.43
RN hours per resident per day1.060.710.69
Weekend RN hours per resident per day0.960.550.48
Nursing staff turnover39.4%43.7%45.3%
RN turnover33.3%41.5%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 4% below weekdays (11% statewide). CMS expects about 4.79 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeIllinoisU.S.
Falls with major injury (long-stay)
F689
2.0%3.0%3.2%
Pressure ulcers (long-stay)
F686
3.6%4.8%4.5%
Antipsychotic medication (long-stay)
F758
24.9%21.7%15.4%
New antipsychotic medication (short-stay)
F758
5.7%2.2%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
22.3%18.4%19.5%
Urinary tract infections (long-stay)
F690
0.0%1.5%1.5%
Catheter left in bladder (long-stay)
F690
0.2%0.8%0.7%
New or worse incontinence (long-stay)
F690
17.5%19.8%18.3%
Losing too much weight (long-stay)
F692
12.4%6.1%5.1%
Needing more help with daily activities (long-stay)
F676
10.3%13.0%13.5%
Walking ability got worse (long-stay)
F676
4.9%12.8%12.7%
Depressive symptoms (long-stay)
F740
73.2%55.9%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
27.4%25.6%23.4%
ER visits (short-stay)
F684
12.3%13.5%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.681.961.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey23 (Illinois average 5.3)
Repeat fire safety tagsE015 (2 cycles), K293 (2 cycles), K311 (3 cycles), K345 (3 cycles), K353 (3 cycles), K531 (2 cycles), K918 (2 cycles), K321 (2 cycles), K351 (2 cycles), K363 (2 cycles), K920 (2 cycles), K511 (2 cycles), K225 (2 cycles)
Fire safety citations on the last survey
E006
F
Conduct risk assessment and an All-Hazards approach.
E015
F
Address subsistence needs for staff and patients.
E022
F
Establish policies and procedures for sheltering.
K211
F
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K291
F
Install emergency lighting that can last at least 1 1/2 hours.
K293
F
Have properly located and lighted "Exit" signs.
K311
F
Have an enclosure around a vertical opening shaft.
K341
F
Install a fire alarm system that can be heard throughout the facility.
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K531
F
Have elevators that firefighters can control in the event of a fire.
K711
F
Provide a written emergency evacuation plan.
K712
F
Have simulated fire drills held at unexpected times.
K915
F
Have proper power supply for life support equipment.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K223
E
Provide exit doors that are held open by devices that will automatically close on the activation…
K321
E
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K324
E
Provide properly protected cooking facilities.
K351
E
Install an approved automatic sprinkler system.
K363
E
Install corridor and hallway doors that block smoke.
K541
E
Install properly constructed and protected linen or trash chutes.
K919
E
Meet requirements for the use of electrical equipment.
K920
E
Ensure proper usage of power strips and extension cords.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.