★ OpsStar

Green Valley Care Center: Survey Readiness Report

3118 Green Valley Rd, New Albany, IN 47150 · CCN 155070 · 141 beds · CMS 4★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Jan 9, 2026 · 10 months ago · previous Nov 6, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  2. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles
  3. Abuse and neglect (F602)
    F602 cited in 2 of the last 3 inspection cycles
  4. Staffing levels and RN coverage (F725)
    2 staffing measures below the state average
  5. Infection prevention and control (F880)
    F880 cited 1 time in the last 3 cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jan 9, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: E · last cited Jan 9, 2026
F602
2 of 3 cycles
Protect each resident from the wrongful use of the resident's belongings or money.
Worst: D · last cited Aug 5, 2025

19 health citations across 16 different tags in the last 3 cycles. Last standard survey: 5 citations (Indiana average 7.2).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles7
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeIndianaU.S.
Total nurse hours per resident per day3.763.733.90
Weekend nurse hours per resident per day3.373.263.43
RN hours per resident per day0.480.680.69
Weekend RN hours per resident per day0.220.460.48
Nursing staff turnover42.3%45.9%45.3%
RN turnover56.3%40.5%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 10% below weekdays (13% statewide). CMS expects about 4.74 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeIndianaU.S.
Falls with major injury (long-stay)
F689
2.4%3.8%3.2%
Pressure ulcers (long-stay)
F686
2.8%3.5%4.5%
Antipsychotic medication (long-stay)
F758
11.8%13.7%15.4%
New antipsychotic medication (short-stay)
F758
1.6%1.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
26.2%23.5%19.5%
Urinary tract infections (long-stay)
F690
1.7%1.1%1.5%
Catheter left in bladder (long-stay)
F690
0.9%0.3%0.7%
New or worse incontinence (long-stay)
F690
21.9%22.4%18.3%
Losing too much weight (long-stay)
F692
5.9%5.3%5.1%
Needing more help with daily activities (long-stay)
F676
2.3%10.8%13.5%
Walking ability got worse (long-stay)
F676
2.6%11.1%12.7%
Depressive symptoms (long-stay)
F740
21.2%25.5%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Sent back to the hospital (short-stay)
F660
18.2%21.8%23.4%
ER visits (short-stay)
F684
5.3%10.9%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.761.511.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey15 (Indiana average 5.6)
Repeat fire safety tagsK222 (3 cycles), K211 (2 cycles), K321 (3 cycles), K351 (2 cycles), K232 (2 cycles), K324 (2 cycles), K363 (2 cycles)
Fire safety citations on the last survey
K222
F
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K271
F
Have exits that are accessible at all times.
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K712
F
Have simulated fire drills held at unexpected times.
K921
F
Ensure that testing and maintenance of electrical equipment is performed.
K211
E
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K321
E
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K351
E
Install an approved automatic sprinkler system.
K361
E
Ensure that waiting areas, nurse’s stations, gift shops, and cooking facilities, open to the…
K372
E
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
K920
E
Ensure proper usage of power strips and extension cords.
K927
E
Have proper fire barriers, ventilation and signs for the transfilling of oxygen.
E039
C
Conduct testing and exercise requirements.
K346
C
Follow proper procedures when the fire alarm was out of service for more than 4 hours.
K354
C
Follow proper procedures when the automatic sprinkler systems was out of service for more than 10…

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.