★ OpsStar

The Vinton Lutheran Home: Survey Readiness Report

1301 Second Avenue South, Vinton, IA 52349 · CCN 165552 · 61 beds · CMS 2★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Apr 30, 2026 · 6 months ago · previous Apr 10, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; F689 cited at harm level K (Oct 21, 2025); F689 cited at harm level G (Dec 4, 2024)
  2. Care plans (F657)
    F657 cited in 2 of the last 3 inspection cycles; Complaint citation for F657 in the past 12 months
  3. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  4. Daily living care (ADLs) (F677, F676)
    Complaint citation for F677 in the past 12 months; Needing more help with daily activities (long-stay): 21.6% vs 16.6% state average
  5. Hospital readmissions and discharge planning (F684)
    Hospitalizations per 1,000 long-stay days: 2.05 vs 1.45 state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: K · last cited Oct 21, 2025
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: E · last cited Apr 10, 2025
F657
2 of 3 cycles
Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a…
Worst: D · last cited Jan 6, 2026

14 health citations across 11 different tags in the last 3 cycles. Last standard survey: 4 citations (Iowa average 6.6).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F689
K
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Immediate jeopardy · Oct 21, 2025 · complaint
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Dec 4, 2024 · complaint

Complaints and infection control

Complaint citations, past 12 months3
Complaint citations, last 3 cycles6
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeIowaU.S.
Total nurse hours per resident per day4.613.863.90
Weekend nurse hours per resident per day3.963.383.43
RN hours per resident per day0.790.740.69
Weekend RN hours per resident per day0.450.510.48
Nursing staff turnover32.0%44.1%45.3%
RN turnover0.0%42.1%42.5%
Administrators who left (past year)1.00.40.5

Weekend nurse staffing is 14% below weekdays (12% statewide). CMS expects about 3.01 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeIowaU.S.
Falls with major injury (long-stay)
F689
2.1%3.9%3.2%
Pressure ulcers (long-stay)
F686
5.1%4.1%4.5%
Antipsychotic medication (long-stay)
F758
11.5%19.8%15.4%
New antipsychotic medication (short-stay)
F758
0.0%2.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
23.3%21.0%19.5%
Urinary tract infections (long-stay)
F690
3.2%2.4%1.5%
Catheter left in bladder (long-stay)
F690
2.3%1.4%0.7%
New or worse incontinence (long-stay)
F690
22.5%25.0%18.3%
Losing too much weight (long-stay)
F692
2.7%4.4%5.1%
Needing more help with daily activities (long-stay)
F676
21.6%16.6%13.5%
Walking ability got worse (long-stay)
F676
12.3%15.2%12.7%
Depressive symptoms (long-stay)
F740
0.6%4.2%13.5%
Physically restrained (long-stay)
F604
0.0%0.2%0.1%
Hospitalizations per 1,000 long-stay days
F684
2.051.451.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey2 (Iowa average 3.6)
Repeat fire safety tagsK321 (2 cycles)
Fire safety citations on the last survey
K712
F
Have simulated fire drills held at unexpected times.
K353
E
Inspect, test, and maintain automatic sprinkler systems.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.