★ OpsStar

Family Health & Rehabilitation Center: Survey Readiness Report

639 S Maize Court, Wichita, KS 67209 · CCN 175501 · 72 beds · CMS 4★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Mar 4, 2026 · 8 months ago · previous Apr 24, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  2. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles
  3. Daily living care (ADLs) (F677)
    F677 cited in 2 of the last 3 inspection cycles
  4. Medication use (F757)
    F757 cited in 2 of the last 3 inspection cycles
  5. Bladder care and infections (F690)
    Catheter left in bladder (long-stay): 2.8% vs 1.4% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited Apr 24, 2024
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: E · last cited Apr 24, 2024
F677
2 of 3 cycles
Provide care and assistance to perform activities of daily living for any resident who is unable.
Worst: D · last cited Mar 4, 2026
F757
2 of 3 cycles
Ensure each resident’s drug regimen must be free from unnecessary drugs.
Worst: D · last cited Apr 24, 2024

24 health citations across 20 different tags in the last 3 cycles. Last standard survey: 7 citations (Kansas average 9.4).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles11
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeKansasU.S.
Total nurse hours per resident per day5.084.133.90
Weekend nurse hours per resident per day4.343.623.43
RN hours per resident per day0.590.730.69
Weekend RN hours per resident per day0.470.510.48
Nursing staff turnover68.4%48.0%45.3%
RN turnover71.4%42.6%42.5%
Administrators who left (past year)0.00.30.5

Weekend nurse staffing is 15% below weekdays (12% statewide). CMS expects about 3.31 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeKansasU.S.
Falls with major injury (long-stay)
F689
7.1%4.2%3.2%
Pressure ulcers (long-stay)
F686
1.3%4.4%4.5%
Antipsychotic medication (long-stay)
F758
3.1%17.7%15.4%
New antipsychotic medication (short-stay)
F758
1.0%1.6%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
11.5%23.4%19.5%
Urinary tract infections (long-stay)
F690
2.4%2.8%1.5%
Catheter left in bladder (long-stay)
F690
2.8%1.4%0.7%
New or worse incontinence (long-stay)
F690
16.4%21.6%18.3%
Losing too much weight (long-stay)
F692
5.8%4.8%5.1%
Needing more help with daily activities (long-stay)
F676
18.2%17.4%13.5%
Walking ability got worse (long-stay)
F676
14.6%14.5%12.7%
Depressive symptoms (long-stay)
F740
1.3%6.6%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Sent back to the hospital (short-stay)
F660
24.0%22.3%23.4%
ER visits (short-stay)
F684
14.3%11.4%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.271.691.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey9 (Kansas average 8.8)
Repeat fire safety tagsK222 (2 cycles), K345 (3 cycles), K372 (3 cycles), K918 (3 cycles), K920 (3 cycles)
Fire safety citations on the last survey
K222
F
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K372
F
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
K511
F
Have properly installed electrical wiring and gas equipment.
K521
F
Ensure heating and ventilation systems that have been properly installed according to the…
K712
F
Have simulated fire drills held at unexpected times.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K920
F
Ensure proper usage of power strips and extension cords.
K923
F
Have proper medical gas storage and administration areas.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.