★ OpsStar

Hilltop Manor Nursing Center: Survey Readiness Report

403 S Valley, Cunningham, KS 67035 · CCN 175545 · 45 beds · CMS 4★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Dec 30, 2025 · 10 months ago · previous Apr 4, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 3 of the last 3 inspection cycles; F689 cited at harm level J (May 12, 2026); F689 cited at harm level G (Apr 4, 2024)
  2. Psychotropic medications (F758)
    Antipsychotic medication (long-stay): 23.8% vs 17.7% state average; New antipsychotic medication (short-stay): 6.8% vs 1.6% state average
  3. Care plans (F657)
    F657 cited in 2 of the last 3 inspection cycles
  4. Pressure ulcers and skin care (F686)
    Pressure ulcers (long-stay): 8.0% vs 4.4% state average
  5. Infection prevention and control (F880)
    F880 cited 1 time in the last 3 cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F689
3 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: J · last cited May 12, 2026
F657
2 of 3 cycles
Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a…
Worst: D · last cited Apr 4, 2024

20 health citations across 16 different tags in the last 3 cycles. Last standard survey: 11 citations (Kansas average 9.4).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F689
J
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Immediate jeopardy · May 12, 2026 · complaint
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Apr 4, 2024

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles1
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeKansasU.S.
Total nurse hours per resident per day4.764.133.90
Weekend nurse hours per resident per day3.943.623.43
RN hours per resident per day1.020.730.69
Weekend RN hours per resident per day0.670.510.48
Nursing staff turnover54.7%48.0%45.3%
RN turnover20.0%42.6%42.5%
Administrators who left (past year)0.00.30.5

Weekend nurse staffing is 17% below weekdays (12% statewide). CMS expects about 3.66 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeKansasU.S.
Falls with major injury (long-stay)
F689
7.7%4.2%3.2%
Pressure ulcers (long-stay)
F686
8.0%4.4%4.5%
Antipsychotic medication (long-stay)
F758
23.8%17.7%15.4%
New antipsychotic medication (short-stay)
F758
6.8%1.6%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
23.9%23.4%19.5%
Urinary tract infections (long-stay)
F690
1.4%2.8%1.5%
Catheter left in bladder (long-stay)
F690
2.4%1.4%0.7%
New or worse incontinence (long-stay)
F690
24.3%21.6%18.3%
Losing too much weight (long-stay)
F692
1.9%4.8%5.1%
Needing more help with daily activities (long-stay)
F676
18.0%17.4%13.5%
Walking ability got worse (long-stay)
F676
13.1%14.5%12.7%
Depressive symptoms (long-stay)
F740
0.0%6.6%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Hospitalizations per 1,000 long-stay days
F684
0.601.691.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $15,288
Payment denials, past 3 yearsNone
Fire safety citations, last survey11 (Kansas average 8.8)
Repeat fire safety tagsK222 (2 cycles), K353 (2 cycles), K372 (2 cycles), K511 (3 cycles), K918 (2 cycles), K920 (3 cycles), K712 (2 cycles)
Fire safety citations on the last survey
K161
F
Use approved construction type or materials.
K222
F
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K324
F
Provide properly protected cooking facilities.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K363
F
Install corridor and hallway doors that block smoke.
K372
F
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
K511
F
Have properly installed electrical wiring and gas equipment.
K741
F
Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where…
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K920
F
Ensure proper usage of power strips and extension cords.
K923
F
Have proper medical gas storage and administration areas.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.