★ OpsStar

Villa Rosa Nursing and Rehabilitation, LLC: Survey Readiness Report

3800 Lottsford Vista Road, Mitchellville, MD 20721 · CCN 215350 · 107 beds · CMS 2★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Jan 14, 2026 · 10 months ago · previous May 31, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Abuse and neglect (F609, F610)
    F609 cited in 2 of the last 3 inspection cycles; F610 cited in 2 of the last 3 inspection cycles; Complaint citation for F609 in the past 12 months
  2. Safe, clean, homelike environment (F584, F909, F921)
    F584 cited in 2 of the last 3 inspection cycles; Complaint citation for F909 in the past 12 months; Complaint citation for F921 in the past 12 months
  3. Care plans (F656, F657)
    F656 cited in 2 of the last 3 inspection cycles; F657 cited in 2 of the last 3 inspection cycles
  4. Resident rights and dignity (F550, F628)
    F550 cited in 2 of the last 3 inspection cycles; Complaint citation for F628 in the past 12 months; Complaint citation for F550 in the past 12 months
  5. Daily living care (ADLs) (F676)
    Needing more help with daily activities (long-stay): 39.6% vs 19.6% state average; Walking ability got worse (long-stay): 40.9% vs 19.9% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jan 14, 2026
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited Jan 14, 2026
F584
2 of 3 cycles
Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to…
Worst: E · last cited Jan 14, 2026
F609
2 of 3 cycles
Timely report suspected abuse, neglect, or theft and report the results of the investigation to proper authorities.
Worst: E · last cited Jan 14, 2026
F610
2 of 3 cycles
Respond appropriately to all alleged violations.
Worst: E · last cited Jan 14, 2026
F656
2 of 3 cycles
Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can…
Worst: E · last cited Jan 14, 2026
F657
2 of 3 cycles
Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a…
Worst: E · last cited Jan 14, 2026
F550
2 of 3 cycles
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her…
Worst: D · last cited Jan 14, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: D · last cited Jan 14, 2026
F842
2 of 3 cycles
Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance…
Worst: D · last cited Jan 14, 2026

48 health citations across 36 different tags in the last 3 cycles. Last standard survey: 22 citations (Maryland average 17.0).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months10
Complaint citations, last 3 cycles18
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeMarylandU.S.
Total nurse hours per resident per day3.393.933.90
Weekend nurse hours per resident per day3.063.493.43
RN hours per resident per day0.700.880.69
Weekend RN hours per resident per day0.610.640.48
Nursing staff turnover19.7%40.2%45.3%
RN turnover8.3%37.8%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 10% below weekdays (11% statewide). CMS expects about 3.89 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeMarylandU.S.
Falls with major injury (long-stay)
F689
1.1%2.5%3.2%
Pressure ulcers (long-stay)
F686
9.4%5.7%4.5%
Antipsychotic medication (long-stay)
F758
12.6%14.1%15.4%
New antipsychotic medication (short-stay)
F758
0.4%1.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
3.7%16.8%19.5%
Urinary tract infections (long-stay)
F690
0.0%1.4%1.5%
Catheter left in bladder (long-stay)
F690
0.2%0.5%0.7%
New or worse incontinence (long-stay)
F690
8.2%24.2%18.3%
Losing too much weight (long-stay)
F692
5.9%5.4%5.1%
Needing more help with daily activities (long-stay)
F676
39.6%19.6%13.5%
Walking ability got worse (long-stay)
F676
40.9%19.9%12.7%
Depressive symptoms (long-stay)
F740
5.8%23.8%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Sent back to the hospital (short-stay)
F660
19.5%20.2%23.4%
ER visits (short-stay)
F684
9.0%9.4%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.281.301.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey15 (Maryland average 8.6)
Repeat fire safety tagsK223 (3 cycles), K324 (2 cycles), K345 (2 cycles), K353 (3 cycles), K712 (2 cycles), K761 (2 cycles), K918 (2 cycles), K363 (2 cycles), K321 (2 cycles), K531 (2 cycles), K271 (2 cycles)
Fire safety citations on the last survey
K223
F
Provide exit doors that are held open by devices that will automatically close on the activation…
K324
F
Provide properly protected cooking facilities.
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K712
F
Have simulated fire drills held at unexpected times.
K761
F
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K363
E
Install corridor and hallway doors that block smoke.
K914
E
Ensure receptacles at patient bed locations and where general anesthesia is administered, are…
K920
E
Ensure proper usage of power strips and extension cords.
K255
D
Ensure that suites are correctly sub-divided by noncombustible or limited-combustible construction.
K293
D
Have properly located and lighted "Exit" signs.
K321
D
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K531
D
Have elevators that firefighters can control in the event of a fire.
K781
D
Have restrictions on the use of portable space heaters.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.