★ OpsStar

Ayer Valley Rehab and Nursing: Survey Readiness Report

400 Groton Road, Ayer, MA 01432 · CCN 225421 · 123 beds · CMS 1★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey May 28, 2026 · 6 months ago · previous Mar 13, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Notifying doctors and families (F580)
    F580 cited in 2 of the last 3 inspection cycles; F580 cited at harm level G (Mar 5, 2024)
  2. Pressure ulcers and skin care (F686)
    F686 cited in 2 of the last 3 inspection cycles; F686 cited at harm level G (Mar 5, 2024)
  3. Infection prevention and control (F880)
    F880 cited in 3 of the last 3 inspection cycles; F880 cited 4 times in the last 3 cycles
  4. Quality of care (F684, F699)
    F684 cited in 2 of the last 3 inspection cycles; F699 cited in 2 of the last 3 inspection cycles
  5. Staffing levels and RN coverage (F726, F725)
    F726 cited in 2 of the last 3 inspection cycles; 2 staffing measures below the state average; Nursing turnover 60.5% vs 37.6% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited May 28, 2026
F580
2 of 3 cycles
Immediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.)…
Worst: G · last cited Mar 13, 2025
F686
2 of 3 cycles
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Worst: G · last cited May 28, 2026
F842
2 of 3 cycles
Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance…
Worst: F · last cited Mar 13, 2025
F804
2 of 3 cycles
Ensure food and drink is palatable, attractive, and at a safe and appetizing temperature.
Worst: E · last cited Mar 13, 2025
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: E · last cited May 28, 2026
F756
2 of 3 cycles
Ensure a licensed pharmacist perform a monthly drug regimen review, including the medical chart, following…
Worst: E · last cited Mar 13, 2025
F585
2 of 3 cycles
Honor the resident's right to voice grievances without discrimination or reprisal and the facility must establish a…
Worst: D · last cited May 28, 2026
F684
2 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: D · last cited May 28, 2026
F699
2 of 3 cycles
Provide care or services that was trauma informed and/or culturally competent.
Worst: D · last cited Mar 13, 2025
F726
2 of 3 cycles
Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that…
Worst: D · last cited Mar 13, 2025
F692
2 of 3 cycles
Provide enough food/fluids to maintain a resident's health.
Worst: D · last cited Jan 2, 2025

74 health citations across 53 different tags in the last 3 cycles. Last standard survey: 15 citations (Massachusetts average 6.4).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F686
G
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Actual harm · Mar 5, 2024
F580
G
Immediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.)…
Actual harm · Mar 5, 2024

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles20
Infection control (F880) citations, last 3 cycles4

Staffing payroll-based journal (PBJ)

MeasureThis homeMassachusettsU.S.
Total nurse hours per resident per day3.583.943.90
Weekend nurse hours per resident per day3.033.523.43
RN hours per resident per day0.820.660.69
Weekend RN hours per resident per day0.610.460.48
Nursing staff turnover60.5%37.6%45.3%
RN turnover39.1%42.7%42.5%
Administrators who left (past year)0.00.40.5

Weekend nurse staffing is 15% below weekdays (11% statewide). CMS expects about 4.09 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeMassachusettsU.S.
Falls with major injury (long-stay)
F689
2.8%3.4%3.2%
Pressure ulcers (long-stay)
F686
2.8%4.2%4.5%
Antipsychotic medication (long-stay)
F758
17.8%21.5%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.4%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
24.2%19.5%19.5%
Urinary tract infections (long-stay)
F690
0.8%1.7%1.5%
Catheter left in bladder (long-stay)
F690
0.4%0.7%0.7%
New or worse incontinence (long-stay)
F690
30.3%20.4%18.3%
Losing too much weight (long-stay)
F692
6.8%5.0%5.1%
Needing more help with daily activities (long-stay)
F676
13.0%15.8%13.5%
Walking ability got worse (long-stay)
F676
4.8%13.9%12.7%
Depressive symptoms (long-stay)
F740
29.1%17.4%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
37.6%25.7%23.4%
ER visits (short-stay)
F684
20.1%11.8%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.951.841.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $53,264
Payment denials, past 3 yearsNone
Fire safety citations, last survey8 (Massachusetts average 3.9)
Repeat fire safety tagsK345 (2 cycles), K353 (3 cycles), K918 (3 cycles), K712 (3 cycles), K324 (2 cycles), K911 (2 cycles), K761 (2 cycles)
Fire safety citations on the last survey
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K351
F
Install an approved automatic sprinkler system.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K712
E
Have simulated fire drills held at unexpected times.
K324
D
Provide properly protected cooking facilities.
K911
D
Meet requirements for the installation and maintenance of electrical systems.
K920
D
Ensure proper usage of power strips and extension cords.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.