Royalton Manor, LLC: Survey Readiness Report

288 Peace Blvd, St Joseph, MI 49085 · CCN 235623 · 123 beds · CMS 1★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jul 9, 2026 · 4 months ago · previous Apr 16, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Quality of care (F658, F684, F693)
    F658 cited in 3 of the last 3 inspection cycles; F684 cited in 2 of the last 3 inspection cycles; F684 cited at harm level G (Oct 3, 2024)
  2. Food safety and kitchen (F812, F804)
    F812 cited in 3 of the last 3 inspection cycles; F804 cited in 2 of the last 3 inspection cycles; Complaint citation for F812 in the past 12 months
  3. Resident rights and dignity (F550, F558, F557)
    F550 cited in 3 of the last 3 inspection cycles; F558 cited in 2 of the last 3 inspection cycles; Complaint citation for F557 in the past 12 months
  4. Pressure ulcers and skin care (F686)
    F686 cited in 2 of the last 3 inspection cycles; F686 cited at harm level G (Apr 3, 2024); Complaint citation for F686 in the past 12 months
  5. Infection prevention and control (F880)
    F880 cited in 3 of the last 3 inspection cycles; Complaint citation for F880 in the past 12 months; F880 cited 3 times in the last 3 cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
3 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jul 9, 2026
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited Jul 9, 2026
F658
3 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: E · last cited Jul 9, 2026
F550
3 of 3 cycles
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her…
Worst: E · last cited Mar 19, 2026
F686
2 of 3 cycles
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Worst: G · last cited Aug 12, 2026
F684
2 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: G · last cited Oct 3, 2024
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: E · last cited Jul 9, 2026
F690
2 of 3 cycles
Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care,…
Worst: E · last cited Jul 9, 2026
F804
2 of 3 cycles
Ensure food and drink is palatable, attractive, and at a safe and appetizing temperature.
Worst: E · last cited Mar 19, 2026
F558
2 of 3 cycles
Reasonably accommodate the needs and preferences of each resident.
Worst: D · last cited Jul 9, 2026
F656
2 of 3 cycles
Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can…
Worst: D · last cited Jul 9, 2026
F842
2 of 3 cycles
Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance…
Worst: D · last cited Jul 9, 2026

63 health citations across 42 different tags in the last 3 cycles. Last standard survey: 19 citations (Michigan average 9.9).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F604
G
Ensure that each resident is free from the use of physical restraints, unless needed for medical treatment.
Actual harm · Apr 16, 2025
F684
G
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Actual harm · Oct 3, 2024 · complaint
F686
G
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Actual harm · Apr 3, 2024 · complaint

Complaints and infection control

Complaint citations, past 12 months10
Complaint citations, last 3 cycles29
Infection control (F880) citations, last 3 cycles3

Staffing payroll-based journal (PBJ)

MeasureThis homeMichiganU.S.
Total nurse hours per resident per day3.394.033.90
Weekend nurse hours per resident per day2.923.503.43
RN hours per resident per day0.810.780.69
Weekend RN hours per resident per day0.460.490.48
Nursing staff turnover36.8%44.6%45.3%
RN turnover37.5%39.2%42.5%
Administrators who left (past year)0.00.40.5

Weekend nurse staffing is 14% below weekdays (13% statewide). CMS expects about 3.43 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeMichiganU.S.
Falls with major injury (long-stay)
F689
3.5%3.0%3.2%
Pressure ulcers (long-stay)
F686
6.5%5.0%4.5%
Antipsychotic medication (long-stay)
F758
9.5%14.7%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
16.6%19.4%19.5%
Urinary tract infections (long-stay)
F690
1.1%1.5%1.5%
Catheter left in bladder (long-stay)
F690
0.8%0.7%0.7%
New or worse incontinence (long-stay)
F690
29.0%19.4%18.3%
Losing too much weight (long-stay)
F692
24.8%5.5%5.1%
Needing more help with daily activities (long-stay)
F676
26.7%10.7%13.5%
Walking ability got worse (long-stay)
F676
31.3%11.1%12.7%
Depressive symptoms (long-stay)
F740
2.9%4.5%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
27.6%23.9%23.4%
ER visits (short-stay)
F684
6.4%11.7%11.8%
Hospitalizations per 1,000 long-stay days
F684
2.021.741.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years2 totaling $173,966
Payment denials, past 3 years1
Fire safety citations, last survey14 (Michigan average 4.8)
Repeat fire safety tagsK321 (3 cycles), K353 (2 cycles), K918 (2 cycles), K920 (3 cycles), K363 (2 cycles)
Fire safety citations on the last survey
K211
F
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K321
F
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K324
F
Provide properly protected cooking facilities.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K511
F
Have properly installed electrical wiring and gas equipment.
K521
F
Ensure heating and ventilation systems that have been properly installed according to the…
K711
F
Provide a written emergency evacuation plan.
K761
F
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K223
E
Provide exit doors that are held open by devices that will automatically close on the activation…
K232
E
Have corridors or aisles that are unobstructed and are at least 8 feet in width.
K355
E
Properly select, install, inspect, or maintain portable fire extinguishes.
K362
E
Ensure that corridors are separated from use areas by walls constructed to limit the passage of…
K920
E
Ensure proper usage of power strips and extension cords.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.