★ OpsStar

Colonial Acres of Humboldt: Survey Readiness Report

1043 10th Street, Humboldt, NE 68376 · CCN 285248 · 49 beds · CMS 2★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Mar 12, 2026 · 8 months ago · previous Oct 3, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  2. Daily living care (ADLs) (F676)
    Needing more help with daily activities (long-stay): 26.7% vs 19.0% state average; Walking ability got worse (long-stay): 25.1% vs 16.8% state average
  3. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  4. Psychotropic medications (F758)
    New antipsychotic medication (short-stay): 14.6% vs 2.1% state average
  5. Bladder care and infections (F690)
    Catheter left in bladder (long-stay): 2.6% vs 1.3% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Mar 12, 2026
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited Mar 12, 2026

15 health citations across 13 different tags in the last 3 cycles. Last standard survey: 9 citations (Nebraska average 7.6).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles3
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeNebraskaU.S.
Total nurse hours per resident per day3.804.123.90
Weekend nurse hours per resident per day3.343.573.43
RN hours per resident per day0.520.690.69
Weekend RN hours per resident per day0.360.480.48
Nursing staff turnover45.2%48.5%45.3%
RN turnover20.0%43.5%42.5%
Administrators who left (past year)1.00.50.5

Weekend nurse staffing is 12% below weekdays (14% statewide). CMS expects about 3.57 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeNebraskaU.S.
Falls with major injury (long-stay)
F689
0.0%4.5%3.2%
Pressure ulcers (long-stay)
F686
2.6%4.0%4.5%
Antipsychotic medication (long-stay)
F758
16.0%20.7%15.4%
New antipsychotic medication (short-stay)
F758
14.6%2.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
11.7%19.0%19.5%
Urinary tract infections (long-stay)
F690
0.8%2.7%1.5%
Catheter left in bladder (long-stay)
F690
2.6%1.3%0.7%
New or worse incontinence (long-stay)
F690
29.5%25.0%18.3%
Losing too much weight (long-stay)
F692
5.0%5.1%5.1%
Needing more help with daily activities (long-stay)
F676
26.7%19.0%13.5%
Walking ability got worse (long-stay)
F676
25.1%16.8%12.7%
Depressive symptoms (long-stay)
F740
2.7%4.4%13.5%
Physically restrained (long-stay)
F604
0.0%0.3%0.1%
Sent back to the hospital (short-stay)
F660
27.0%21.1%23.4%
ER visits (short-stay)
F684
5.2%10.8%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.831.671.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey22 (Nebraska average 5.4)
Repeat fire safety tagsK222 (2 cycles), K321 (3 cycles), K324 (2 cycles), K345 (3 cycles), K353 (2 cycles), K354 (2 cycles), K363 (2 cycles), K511 (2 cycles), K712 (2 cycles), K914 (2 cycles), K919 (2 cycles), K920 (3 cycles), K921 (3 cycles)
Fire safety citations on the last survey
K100
F
Meet other general requirements.
K211
F
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K222
F
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K300
F
Meet other general requirements that are deficient.
K321
F
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K324
F
Provide properly protected cooking facilities.
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K354
F
Follow proper procedures when the automatic sprinkler systems was out of service for more than 10…
K363
F
Install corridor and hallway doors that block smoke.
K500
F
Meet other general requirements that are deficient.
K511
F
Have properly installed electrical wiring and gas equipment.
K711
F
Provide a written emergency evacuation plan.
K712
F
Have simulated fire drills held at unexpected times.
K781
F
Have restrictions on the use of portable space heaters.
K914
F
Ensure receptacles at patient bed locations and where general anesthesia is administered, are…
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K919
F
Meet requirements for the use of electrical equipment.
K920
F
Ensure proper usage of power strips and extension cords.
K921
F
Ensure that testing and maintenance of electrical equipment is performed.
K923
F
Have proper medical gas storage and administration areas.
K523
D
Ensure that HVAC heat units are suspended and out of the reach of patients and can be shut off if…

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.