★ OpsStar

Elm Wood Center at Claremont: Survey Readiness Report

290 Hanover Street, Claremont, NH 03743 · CCN 305041 · 68 beds · CMS 2★ overall

Past the 15-month federal limit: a survey could come any day
Last standard survey Aug 1, 2025 · 15 months ago · previous Jun 13, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Staffing levels and RN coverage (F725)
    3 staffing measures below the state average; Weekend staffing drops 17% vs 11% statewide; Nursing turnover 55.4% vs 43.4% state average
  2. Medication use (F759)
    F759 cited in 2 of the last 3 inspection cycles
  3. Administration (F838)
    F838 cited in 2 of the last 3 inspection cycles
  4. Quality of care (F658)
    F658 cited in 2 of the last 3 inspection cycles
  5. Hospital readmissions and discharge planning (F684)
    ER visits (short-stay): 20.9% vs 13.0% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F759
2 of 3 cycles
Ensure medication error rates are not 5 percent or greater.
Worst: E · last cited Jun 13, 2024
F838
2 of 3 cycles
Conduct and document a facility-wide assessment to determine what resources are necessary to care for residents…
Worst: D · last cited Aug 1, 2025
F658
2 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: D · last cited Jun 13, 2024

29 health citations across 26 different tags in the last 3 cycles. Last standard survey: 6 citations (New Hampshire average 4.1).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles1
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeNew HampshireU.S.
Total nurse hours per resident per day3.383.873.90
Weekend nurse hours per resident per day2.793.433.43
RN hours per resident per day0.770.780.69
Weekend RN hours per resident per day0.450.540.48
Nursing staff turnover55.4%43.4%45.3%
RN turnover41.7%40.5%42.5%
Administrators who left (past year)2.00.30.5

Weekend nurse staffing is 17% below weekdays (11% statewide). CMS expects about 4.01 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeNew HampshireU.S.
Falls with major injury (long-stay)
F689
5.9%4.5%3.2%
Pressure ulcers (long-stay)
F686
3.0%4.3%4.5%
Antipsychotic medication (long-stay)
F758
12.8%17.9%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.2%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
19.9%19.1%19.5%
Urinary tract infections (long-stay)
F690
0.0%2.2%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.9%0.7%
New or worse incontinence (long-stay)
F690
23.5%25.4%18.3%
Losing too much weight (long-stay)
F692
4.0%5.2%5.1%
Needing more help with daily activities (long-stay)
F676
23.4%22.3%13.5%
Walking ability got worse (long-stay)
F676
12.9%15.8%12.7%
Depressive symptoms (long-stay)
F740
8.0%15.8%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
16.1%21.8%23.4%
ER visits (short-stay)
F684
20.9%13.0%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.391.721.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey6 (New Hampshire average 2.6)
Repeat fire safety tagsK223 (2 cycles), K918 (2 cycles), K712 (2 cycles)
Fire safety citations on the last survey
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K223
D
Provide exit doors that are held open by devices that will automatically close on the activation…
K913
D
Ensure operating rooms are properly protected and written records are maintained and available for…
K918
D
Have generator or other power source capable of supplying service within 10 seconds.
K712
C
Have simulated fire drills held at unexpected times.
K923
B
Have proper medical gas storage and administration areas.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.