★ OpsStar

Complete Care at Regent LLC: Survey Readiness Report

50 Polifly Road, Hackensack, NJ 07601 · CCN 315295 · 180 beds · CMS 3★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jul 28, 2026 · 4 months ago · previous Feb 3, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Quality of care (F658, F684)
    F658 cited in 3 of the last 3 inspection cycles; F684 cited in 3 of the last 3 inspection cycles
  2. Resident rights and dignity (F558, F628)
    F558 cited in 2 of the last 3 inspection cycles; Complaint citation for F628 in the past 12 months
  3. Safe, clean, homelike environment (F584)
    F584 cited in 2 of the last 3 inspection cycles
  4. Respiratory care (F695)
    F695 cited in 2 of the last 3 inspection cycles
  5. Resident assessments (MDS) (F641)
    F641 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F658
3 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: D · last cited Jul 28, 2026
F684
3 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: D · last cited Jul 28, 2026
F584
2 of 3 cycles
Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to…
Worst: E · last cited Jul 28, 2026
F695
2 of 3 cycles
Provide safe and appropriate respiratory care for a resident when needed.
Worst: E · last cited Jul 28, 2026
F641
2 of 3 cycles
Ensure each resident receives an accurate assessment.
Worst: E · last cited Feb 3, 2025
F558
2 of 3 cycles
Reasonably accommodate the needs and preferences of each resident.
Worst: D · last cited Jul 28, 2026

38 health citations across 30 different tags in the last 3 cycles. Last standard survey: 15 citations (New Jersey average 8.6).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months2
Complaint citations, last 3 cycles5
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeNew JerseyU.S.
Total nurse hours per resident per day3.303.903.90
Weekend nurse hours per resident per day3.003.503.43
RN hours per resident per day0.500.700.69
Weekend RN hours per resident per day0.440.500.48
Nursing staff turnover28.3%39.3%45.3%
RN turnover20.8%37.2%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 9% below weekdays (10% statewide). CMS expects about 3.73 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeNew JerseyU.S.
Falls with major injury (long-stay)
F689
0.9%2.3%3.2%
Pressure ulcers (long-stay)
F686
4.0%5.3%4.5%
Antipsychotic medication (long-stay)
F758
8.2%12.9%15.4%
New antipsychotic medication (short-stay)
F758
1.8%1.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
13.2%18.8%19.5%
Urinary tract infections (long-stay)
F690
0.4%0.7%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.5%0.7%
New or worse incontinence (long-stay)
F690
30.0%15.2%18.3%
Losing too much weight (long-stay)
F692
4.0%4.7%5.1%
Needing more help with daily activities (long-stay)
F676
8.6%8.3%13.5%
Walking ability got worse (long-stay)
F676
6.8%7.3%12.7%
Depressive symptoms (long-stay)
F740
5.8%12.5%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
20.4%24.1%23.4%
ER visits (short-stay)
F684
7.4%8.1%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.561.961.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey5 (New Jersey average 6.6)
Repeat fire safety tagsK345 (3 cycles), K353 (3 cycles), K521 (2 cycles)
Fire safety citations on the last survey
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K521
F
Ensure heating and ventilation systems that have been properly installed according to the…
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K293
E
Have properly located and lighted "Exit" signs.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.