Tallwoods Care Center: Survey Readiness Report

18 Butler Boulevard, Bayville, NJ 08721 · CCN 315462 · 180 beds · CMS 3★ overall

In the survey window: likely within the next 3 months
Last standard survey Nov 26, 2025 · 12 months ago · previous Apr 16, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Abuse and neglect (F600)
    F600 cited in 2 of the last 3 inspection cycles; F600 cited at harm level J (Apr 16, 2024)
  2. Food safety and kitchen (F812)
    F812 cited in 3 of the last 3 inspection cycles
  3. Staffing levels and RN coverage (F725)
    3 staffing measures below the state average; Weekend staffing drops 16% vs 10% statewide
  4. Care plans (F656)
    F656 cited in 2 of the last 3 inspection cycles
  5. Bladder care and infections (F690)
    New or worse incontinence (long-stay): 27.0% vs 15.2% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
3 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Nov 26, 2025
F600
2 of 3 cycles
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Worst: J · last cited Apr 16, 2024
F656
2 of 3 cycles
Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can…
Worst: E · last cited Nov 26, 2025

18 health citations across 14 different tags in the last 3 cycles. Last standard survey: 10 citations (New Jersey average 8.6).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F600
J
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Immediate jeopardy · Apr 16, 2024 · complaint

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles3
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeNew JerseyU.S.
Total nurse hours per resident per day3.193.903.90
Weekend nurse hours per resident per day2.683.503.43
RN hours per resident per day0.550.700.69
Weekend RN hours per resident per day0.510.500.48
Nursing staff turnover41.8%39.3%45.3%
RN turnover40.0%37.2%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 16% below weekdays (10% statewide). CMS expects about 3.65 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeNew JerseyU.S.
Falls with major injury (long-stay)
F689
0.4%2.3%3.2%
Pressure ulcers (long-stay)
F686
8.2%5.3%4.5%
New antipsychotic medication (short-stay)
F758
0.0%1.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
22.9%18.8%19.5%
Urinary tract infections (long-stay)
F690
0.0%0.7%1.5%
Catheter left in bladder (long-stay)
F690
0.4%0.5%0.7%
New or worse incontinence (long-stay)
F690
27.0%15.2%18.3%
Losing too much weight (long-stay)
F692
4.4%4.7%5.1%
Needing more help with daily activities (long-stay)
F676
0.7%8.3%13.5%
Walking ability got worse (long-stay)
F676
3.4%7.3%12.7%
Depressive symptoms (long-stay)
F740
3.1%12.5%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
25.4%24.1%23.4%
ER visits (short-stay)
F684
10.6%8.1%11.8%
Hospitalizations per 1,000 long-stay days
F684
2.331.961.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $13,452
Payment denials, past 3 yearsNone
Fire safety citations, last survey7 (New Jersey average 6.6)
Repeat fire safety tagsNone
Fire safety citations on the last survey
K222
F
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K281
E
Install proper backup exit lighting.
K353
E
Inspect, test, and maintain automatic sprinkler systems.
K374
E
Install smoke barrier doors that can resist smoke for at least 20 minutes.
K531
E
Have elevators that firefighters can control in the event of a fire.
K921
E
Ensure that testing and maintenance of electrical equipment is performed.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.