★ OpsStar

Manhattanview Ctr for Rehabilitation and Healthcar: Survey Readiness Report

3200 Hudson Avenue, Union City, NJ 07087 · CCN 315465 · 127 beds · CMS 4★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Dec 19, 2025 · 11 months ago · previous May 17, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  2. Quality of care (F658)
    F658 cited in 2 of the last 3 inspection cycles
  3. Psychotropic medications (F758)
    New antipsychotic medication (short-stay): 2.8% vs 1.1% state average
  4. Staffing levels and RN coverage (F725)
    4 staffing measures below the state average
  5. Hospital readmissions and discharge planning (F684)
    Hospitalizations per 1,000 long-stay days: 2.42 vs 1.96 state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited May 17, 2024
F658
2 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: D · last cited May 17, 2024

18 health citations across 16 different tags in the last 3 cycles. Last standard survey: 0 citations (New Jersey average 8.6).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles1
Infection control (F880) citations, last 3 cycles0

Staffing payroll-based journal (PBJ)

MeasureThis homeNew JerseyU.S.
Total nurse hours per resident per day3.383.903.90
Weekend nurse hours per resident per day3.033.503.43
RN hours per resident per day0.270.700.69
Weekend RN hours per resident per day0.220.500.48
Nursing staff turnover39.2%39.3%45.3%
RN turnover50.0%37.2%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 11% below weekdays (10% statewide). CMS expects about 4.28 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeNew JerseyU.S.
Falls with major injury (long-stay)
F689
2.3%2.3%3.2%
Pressure ulcers (long-stay)
F686
2.3%5.3%4.5%
Antipsychotic medication (long-stay)
F758
13.1%12.9%15.4%
New antipsychotic medication (short-stay)
F758
2.8%1.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
22.5%18.8%19.5%
Urinary tract infections (long-stay)
F690
1.4%0.7%1.5%
Catheter left in bladder (long-stay)
F690
0.1%0.5%0.7%
New or worse incontinence (long-stay)
F690
5.1%15.2%18.3%
Losing too much weight (long-stay)
F692
1.4%4.7%5.1%
Needing more help with daily activities (long-stay)
F676
9.1%8.3%13.5%
Walking ability got worse (long-stay)
F676
2.1%7.3%12.7%
Depressive symptoms (long-stay)
F740
13.3%12.5%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
20.1%24.1%23.4%
ER visits (short-stay)
F684
8.9%8.1%11.8%
Hospitalizations per 1,000 long-stay days
F684
2.421.961.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey6 (New Jersey average 6.6)
Repeat fire safety tagsNone
Fire safety citations on the last survey
K161
F
Use approved construction type or materials.
K271
F
Have exits that are accessible at all times.
K293
F
Have properly located and lighted "Exit" signs.
K311
F
Have an enclosure around a vertical opening shaft.
K351
F
Install an approved automatic sprinkler system.
K712
F
Have simulated fire drills held at unexpected times.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.