★ OpsStar

Casa Real: Survey Readiness Report

1650 Galisteo Street, Santa Fe, NM 87505 · CCN 325038 · 118 beds

CMS Special Focus Facility status: SFF

CMS abuse icon: cited for abuse in the past year or in each of the past 2 years.

Recently surveyed: next standard survey not expected yet
Last standard survey Jul 23, 2026 · 4 months ago · previous Jan 6, 2026
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Quality of care (F684, F658, F679, F698, F791)
    F684 cited in 2 of the last 3 inspection cycles; F658 cited in 2 of the last 3 inspection cycles; F679 cited in 2 of the last 3 inspection cycles
  2. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; F689 cited at harm level G (Aug 7, 2024); Falls with major injury (long-stay): 6.3% vs 3.4% state average
  3. Abuse and neglect (F600)
    F600 cited in 2 of the last 3 inspection cycles; F600 cited at harm level G (Jul 23, 2026); F600 cited at harm level G (Sep 24, 2024)
  4. Pressure ulcers and skin care (F686)
    F686 cited in 2 of the last 3 inspection cycles; F686 cited at harm level K (Jul 16, 2024)
  5. Care plans (F657, F645, F661)
    F657 cited in 2 of the last 3 inspection cycles; F645 cited in 2 of the last 3 inspection cycles; F661 cited at harm level G (Jul 16, 2024)

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited Apr 8, 2026
F761
3 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: E · last cited Aug 28, 2026
F686
2 of 3 cycles
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Worst: K · last cited Mar 27, 2025
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: G · last cited Jan 6, 2026
F600
2 of 3 cycles
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Worst: G · last cited Jul 23, 2026
F684
2 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: G · last cited Oct 24, 2024
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jan 6, 2026
F725
2 of 3 cycles
Provide enough nursing staff every day to meet the needs of every resident; and have a licensed nurse in charge on…
Worst: F · last cited Jan 6, 2026
F657
2 of 3 cycles
Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a…
Worst: E · last cited Jan 6, 2026
F658
2 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: E · last cited Jan 6, 2026
F584
2 of 3 cycles
Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to…
Worst: E · last cited Aug 28, 2026
F679
2 of 3 cycles
Provide activities to meet all resident's needs.
Worst: E · last cited Jul 23, 2026
F585
2 of 3 cycles
Honor the resident's right to voice grievances without discrimination or reprisal and the facility must establish a…
Worst: E · last cited Jul 23, 2026
F756
2 of 3 cycles
Ensure a licensed pharmacist perform a monthly drug regimen review, including the medical chart, following…
Worst: E · last cited Jan 6, 2026
F677
2 of 3 cycles
Provide care and assistance to perform activities of daily living for any resident who is unable.
Worst: E · last cited Jan 6, 2026
F698
2 of 3 cycles
Provide safe, appropriate dialysis care/services for a resident who requires such services.
Worst: E · last cited Jan 6, 2026
F921
2 of 3 cycles
Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
Worst: E · last cited Jan 23, 2025
F645
2 of 3 cycles
PASARR screening for Mental disorders or Intellectual Disabilities
Worst: D · last cited Jul 23, 2026
F791
2 of 3 cycles
Provide or obtain dental services for each resident.
Worst: D · last cited Jul 23, 2026
F842
2 of 3 cycles
Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance…
Worst: D · last cited Mar 26, 2026

83 health citations across 54 different tags in the last 3 cycles. Last standard survey: 18 citations (New Mexico average 17.4).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F600
G
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Actual harm · Jul 23, 2026
F600
G
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Actual harm · Sep 24, 2024 · complaint
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Aug 7, 2024 · complaint
F684
G
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Actual harm · Jul 16, 2024
F661
G
Ensure necessary information is communicated to the resident, and receiving health care provider at the time of a…
Actual harm · Jul 16, 2024
F692
H
Provide enough food/fluids to maintain a resident's health.
Actual harm · Jul 16, 2024
F686
K
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Immediate jeopardy · Jul 16, 2024

Complaints and infection control

Complaint citations, past 12 months14
Complaint citations, last 3 cycles36
Infection control (F880) citations, last 3 cycles4

Staffing payroll-based journal (PBJ)

MeasureThis homeNew MexicoU.S.
Total nurse hours per resident per day3.613.583.90
Weekend nurse hours per resident per day3.083.143.43
RN hours per resident per day0.330.650.69
Weekend RN hours per resident per day0.170.480.48
Nursing staff turnover62.0%53.5%45.3%
RN turnover66.7%54.0%42.5%
Administrators who left (past year)1.00.90.5

Weekend nurse staffing is 15% below weekdays (12% statewide). CMS expects about 3.37 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeNew MexicoU.S.
Falls with major injury (long-stay)
F689
6.3%3.4%3.2%
Pressure ulcers (long-stay)
F686
3.7%5.2%4.5%
Antipsychotic medication (long-stay)
F758
28.9%14.5%15.4%
New antipsychotic medication (short-stay)
F758
1.2%1.2%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
19.7%14.8%19.5%
Urinary tract infections (long-stay)
F690
1.1%1.0%1.5%
Catheter left in bladder (long-stay)
F690
0.8%0.8%0.7%
New or worse incontinence (long-stay)
F690
27.0%19.2%18.3%
Losing too much weight (long-stay)
F692
7.0%3.5%5.1%
Needing more help with daily activities (long-stay)
F676
9.4%10.3%13.5%
Walking ability got worse (long-stay)
F676
8.7%10.3%12.7%
Depressive symptoms (long-stay)
F740
2.5%2.2%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Sent back to the hospital (short-stay)
F660
27.5%22.1%23.4%
ER visits (short-stay)
F684
16.0%15.7%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.571.491.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years4 totaling $242,371
Payment denials, past 3 years2
Fire safety citations, last survey26 (New Mexico average 9.8)
Repeat fire safety tagsK353 (2 cycles), K712 (3 cycles), K918 (2 cycles), K211 (2 cycles), K293 (2 cycles), K355 (2 cycles), K363 (2 cycles), K761 (2 cycles), K223 (2 cycles), K324 (3 cycles), E007 (2 cycles)
Fire safety citations on the last survey
E037
F
Establish staff and initial training requirements.
E039
F
Conduct testing and exercise requirements.
K100
F
Meet other general requirements.
K291
F
Install emergency lighting that can last at least 1 1/2 hours.
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K346
F
Follow proper procedures when the fire alarm was out of service for more than 4 hours.
K351
F
Install an approved automatic sprinkler system.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K712
F
Have simulated fire drills held at unexpected times.
K741
F
Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where…
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K920
F
Ensure proper usage of power strips and extension cords.
K926
F
Ensure that personnel concerned with handling of medical gases and cylinders are trained on the…
K211
E
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K222
E
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K293
E
Have properly located and lighted "Exit" signs.
K355
E
Properly select, install, inspect, or maintain portable fire extinguishes.
K363
E
Install corridor and hallway doors that block smoke.
K372
E
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
K761
E
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
K914
E
Ensure receptacles at patient bed locations and where general anesthesia is administered, are…
K923
E
Have proper medical gas storage and administration areas.
K223
D
Provide exit doors that are held open by devices that will automatically close on the activation…
K281
D
Install proper backup exit lighting.
K324
D
Provide properly protected cooking facilities.
K911
D
Meet requirements for the installation and maintenance of electrical systems.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.