★ OpsStar

Katherine Luther Residential Hlth Care & Rehab: Survey Readiness Report

110 Utica Road, Clinton, NY 13323 · CCN 335006 · 280 beds · CMS 1★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jun 26, 2026 · 5 months ago · previous Aug 7, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Daily living care (ADLs) (F677, F676)
    F677 cited in 2 of the last 3 inspection cycles; F677 cited at harm level G (Jun 26, 2026); Needing more help with daily activities (long-stay): 23.4% vs 13.7% state average
  2. Quality of care (F684)
    F684 cited in 2 of the last 3 inspection cycles; F684 cited at harm level G (May 9, 2025); F684 cited at harm level J (May 24, 2024)
  3. Nutrition and weight loss (F692)
    F692 cited in 2 of the last 3 inspection cycles; F692 cited at harm level H (Jun 26, 2026)
  4. Pressure ulcers and skin care (F686)
    F686 cited in 2 of the last 3 inspection cycles; F686 cited at harm level G (Jun 26, 2026)
  5. Infection prevention and control (F880)
    F880 cited in 3 of the last 3 inspection cycles; F880 cited 3 times in the last 3 cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F584
3 of 3 cycles
Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to…
Worst: E · last cited Jun 26, 2026
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Jun 26, 2026
F684
2 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: J · last cited May 9, 2025
F692
2 of 3 cycles
Provide enough food/fluids to maintain a resident's health.
Worst: H · last cited Jun 26, 2026
F677
2 of 3 cycles
Provide care and assistance to perform activities of daily living for any resident who is unable.
Worst: G · last cited Jun 26, 2026
F686
2 of 3 cycles
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Worst: G · last cited Jun 26, 2026
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jun 26, 2026
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: E · last cited Jun 26, 2026
F550
2 of 3 cycles
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her…
Worst: D · last cited Jun 26, 2026

35 health citations across 23 different tags in the last 3 cycles. Last standard survey: 12 citations (New York average 8.1).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F686
G
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Actual harm · Jun 26, 2026
F677
G
Provide care and assistance to perform activities of daily living for any resident who is unable.
Actual harm · Jun 26, 2026
F600
G
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Actual harm · Jun 26, 2026 · complaint
F692
H
Provide enough food/fluids to maintain a resident's health.
Actual harm · Jun 26, 2026
F684
G
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Actual harm · May 9, 2025 · complaint
F684
J
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Immediate jeopardy · May 24, 2024 · complaint

Complaints and infection control

Complaint citations, past 12 months2
Complaint citations, last 3 cycles7
Infection control (F880) citations, last 3 cycles3

Staffing payroll-based journal (PBJ)

MeasureThis homeNew YorkU.S.
Total nurse hours per resident per day3.393.693.90
Weekend nurse hours per resident per day2.933.203.43
RN hours per resident per day0.530.730.69
Weekend RN hours per resident per day0.300.490.48
Nursing staff turnover39.5%40.3%45.3%
RN turnover40.0%39.6%42.5%
Administrators who left (past year)1.00.50.5

Weekend nurse staffing is 14% below weekdays (13% statewide). CMS expects about 3.67 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeNew YorkU.S.
Falls with major injury (long-stay)
F689
5.6%3.1%3.2%
Pressure ulcers (long-stay)
F686
1.4%6.5%4.5%
Antipsychotic medication (long-stay)
F758
11.3%13.7%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
16.9%13.2%19.5%
Urinary tract infections (long-stay)
F690
0.7%1.2%1.5%
Catheter left in bladder (long-stay)
F690
0.3%0.5%0.7%
New or worse incontinence (long-stay)
F690
21.0%18.6%18.3%
Losing too much weight (long-stay)
F692
3.8%5.7%5.1%
Needing more help with daily activities (long-stay)
F676
23.4%13.7%13.5%
Walking ability got worse (long-stay)
F676
19.7%11.1%12.7%
Depressive symptoms (long-stay)
F740
2.7%20.1%13.5%
Physically restrained (long-stay)
F604
0.0%0.2%0.1%
Sent back to the hospital (short-stay)
F660
15.6%20.6%23.4%
ER visits (short-stay)
F684
16.6%9.4%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.641.671.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years3 totaling $283,358
Payment denials, past 3 yearsNone
Fire safety citations, last survey10 (New York average 5.7)
Repeat fire safety tagsK353 (2 cycles), K211 (3 cycles), K363 (2 cycles), K920 (2 cycles), K921 (2 cycles), K321 (2 cycles)
Fire safety citations on the last survey
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K712
F
Have simulated fire drills held at unexpected times.
K211
E
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K225
E
Have stairways and smokeproof enclosures used as exits that meet safety requirements.
K363
E
Install corridor and hallway doors that block smoke.
K920
E
Ensure proper usage of power strips and extension cords.
K921
E
Ensure that testing and maintenance of electrical equipment is performed.
K222
D
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K321
D
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K521
D
Ensure heating and ventilation systems that have been properly installed according to the…

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.