★ OpsStar

Crown Heights Center for Nursing and Rehabilitatio: Survey Readiness Report

810 20 St. Marks Avenue, Brooklyn, NY 11213 · CCN 335609 · 295 beds · CMS 3★ overall

Past the 15-month federal limit: a survey could come any day
Last standard survey Dec 19, 2024 · 23 months ago · previous Nov 1, 2022
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Safe, clean, homelike environment (F584, F925)
    F584 cited in 2 of the last 3 inspection cycles; F925 cited in 2 of the last 3 inspection cycles
  2. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  3. Quality of care (F684)
    F684 cited in 2 of the last 3 inspection cycles; Complaint citation for F684 in the past 12 months
  4. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  5. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F584
2 of 3 cycles
Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to…
Worst: E · last cited Dec 19, 2024
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: E · last cited Dec 19, 2024
F684
2 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: D · last cited Feb 4, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: D · last cited Dec 19, 2024
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: D · last cited Dec 19, 2024
F925
2 of 3 cycles
Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.
Worst: D · last cited Dec 19, 2024

29 health citations across 22 different tags in the last 3 cycles. Last standard survey: 17 citations (New York average 8.1).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months5
Complaint citations, last 3 cycles8
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeNew YorkU.S.
Total nurse hours per resident per day3.553.693.90
Weekend nurse hours per resident per day2.913.203.43
RN hours per resident per day0.860.730.69
Weekend RN hours per resident per day0.460.490.48
Nursing staff turnover32.9%40.3%45.3%
RN turnover53.2%39.6%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 18% below weekdays (13% statewide). CMS expects about 4.03 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeNew YorkU.S.
Falls with major injury (long-stay)
F689
1.6%3.1%3.2%
Pressure ulcers (long-stay)
F686
6.5%6.5%4.5%
Antipsychotic medication (long-stay)
F758
12.0%13.7%15.4%
New antipsychotic medication (short-stay)
F758
0.5%1.1%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
6.9%13.2%19.5%
Urinary tract infections (long-stay)
F690
0.8%1.2%1.5%
Catheter left in bladder (long-stay)
F690
0.1%0.5%0.7%
New or worse incontinence (long-stay)
F690
13.3%18.6%18.3%
Losing too much weight (long-stay)
F692
5.8%5.7%5.1%
Needing more help with daily activities (long-stay)
F676
11.4%13.7%13.5%
Walking ability got worse (long-stay)
F676
5.2%11.1%12.7%
Depressive symptoms (long-stay)
F740
6.5%20.1%13.5%
Physically restrained (long-stay)
F604
0.0%0.2%0.1%
Sent back to the hospital (short-stay)
F660
25.3%20.6%23.4%
ER visits (short-stay)
F684
2.0%9.4%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.201.671.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey12 (New York average 5.7)
Repeat fire safety tagsK355 (2 cycles), K161 (2 cycles), K353 (2 cycles), K363 (2 cycles)
Fire safety citations on the last survey
K355
F
Properly select, install, inspect, or maintain portable fire extinguishes.
K161
E
Use approved construction type or materials.
K211
E
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K225
E
Have stairways and smokeproof enclosures used as exits that meet safety requirements.
K321
E
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K353
E
Inspect, test, and maintain automatic sprinkler systems.
K911
E
Meet requirements for the installation and maintenance of electrical systems.
K281
D
Install proper backup exit lighting.
K351
D
Install an approved automatic sprinkler system.
K920
D
Ensure proper usage of power strips and extension cords.
K346
C
Follow proper procedures when the fire alarm was out of service for more than 4 hours.
K354
C
Follow proper procedures when the automatic sprinkler systems was out of service for more than 10…

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.