★ OpsStar

Givens Health Center: Survey Readiness Report

600 Barrett Lane, Asheville, NC 28803 · CCN 345328 · 70 beds · CMS 5★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Mar 18, 2026 · 8 months ago · previous Feb 6, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Daily living care (ADLs) (F676)
    Needing more help with daily activities (long-stay): 35.5% vs 15.0% state average; Walking ability got worse (long-stay): 42.3% vs 16.6% state average
  2. Bladder care and infections (F690)
    Catheter left in bladder (long-stay): 1.7% vs 0.6% state average; New or worse incontinence (long-stay): 29.1% vs 19.9% state average
  3. Resident assessments (MDS) (F641)
    F641 cited in 2 of the last 3 inspection cycles
  4. Respiratory care (F695)
    F695 cited in 2 of the last 3 inspection cycles
  5. Accidents and falls (F689)
    Falls with major injury (long-stay): 5.7% vs 3.4% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F641
2 of 3 cycles
Ensure each resident receives an accurate assessment.
Worst: D · last cited Mar 18, 2026
F695
2 of 3 cycles
Provide safe and appropriate respiratory care for a resident when needed.
Worst: D · last cited Feb 6, 2025

19 health citations across 17 different tags in the last 3 cycles. Last standard survey: 1 citations (North Carolina average 4.6).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles0
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeNorth CarolinaU.S.
Total nurse hours per resident per day5.173.873.90
Weekend nurse hours per resident per day4.383.403.43
RN hours per resident per day1.140.620.69
Weekend RN hours per resident per day0.800.410.48
Nursing staff turnover36.8%48.7%45.3%
RN turnover41.2%45.7%42.5%
Administrators who left (past year)0.00.60.5

Weekend nurse staffing is 15% below weekdays (12% statewide). CMS expects about 3.43 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeNorth CarolinaU.S.
Falls with major injury (long-stay)
F689
5.7%3.4%3.2%
Pressure ulcers (long-stay)
F686
3.1%5.4%4.5%
Antipsychotic medication (long-stay)
F758
15.6%13.9%15.4%
New antipsychotic medication (short-stay)
F758
0.3%1.4%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
13.0%21.1%19.5%
Urinary tract infections (long-stay)
F690
2.4%2.1%1.5%
Catheter left in bladder (long-stay)
F690
1.7%0.6%0.7%
New or worse incontinence (long-stay)
F690
29.1%19.9%18.3%
Losing too much weight (long-stay)
F692
5.6%7.1%5.1%
Needing more help with daily activities (long-stay)
F676
35.5%15.0%13.5%
Walking ability got worse (long-stay)
F676
42.3%16.6%12.7%
Depressive symptoms (long-stay)
F740
7.8%6.8%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Sent back to the hospital (short-stay)
F660
22.1%22.2%23.4%
ER visits (short-stay)
F684
8.3%12.7%11.8%
Hospitalizations per 1,000 long-stay days
F684
2.321.691.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey7 (North Carolina average 4.0)
Repeat fire safety tagsK222 (2 cycles), K353 (2 cycles), K511 (2 cycles), K918 (3 cycles)
Fire safety citations on the last survey
K222
D
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K271
D
Have exits that are accessible at all times.
K321
D
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K353
D
Inspect, test, and maintain automatic sprinkler systems.
K511
D
Have properly installed electrical wiring and gas equipment.
K521
D
Ensure heating and ventilation systems that have been properly installed according to the…
K918
D
Have generator or other power source capable of supplying service within 10 seconds.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.