★ OpsStar

Life Care Center of Westlake: Survey Readiness Report

26520 Center Ridge Rd, Westlake, OH 44145 · CCN 365048 · 119 beds · CMS 2★ overall

Past the 15-month federal limit: a survey could come any day
Last standard survey Oct 19, 2023 · 37 months ago · previous Feb 27, 2020
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Quality of care (F684, F658, F678)
    F684 cited in 3 of the last 3 inspection cycles; Complaint citation for F658 in the past 12 months; Complaint citation for F684 in the past 12 months
  2. Abuse and neglect (F609, F607, F610)
    F609 cited in 2 of the last 3 inspection cycles; Complaint citation for F607 in the past 12 months; Complaint citation for F609 in the past 12 months
  3. Food safety and kitchen (F812)
    F812 cited in 3 of the last 3 inspection cycles
  4. Medical records (F842)
    F842 cited in 2 of the last 3 inspection cycles; Complaint citation for F842 in the past 12 months
  5. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
3 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Oct 19, 2023
F684
3 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: D · last cited Jun 8, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: E · last cited Oct 19, 2023
F842
2 of 3 cycles
Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance…
Worst: D · last cited Feb 26, 2026
F609
2 of 3 cycles
Timely report suspected abuse, neglect, or theft and report the results of the investigation to proper authorities.
Worst: D · last cited Dec 11, 2025

36 health citations across 26 different tags in the last 3 cycles. Last standard survey: 21 citations (Ohio average 10.5).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months15
Complaint citations, last 3 cycles21
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeOhioU.S.
Total nurse hours per resident per day3.713.713.90
Weekend nurse hours per resident per day3.243.293.43
RN hours per resident per day0.610.640.69
Weekend RN hours per resident per day0.400.430.48
Nursing staff turnover41.8%49.0%45.3%
RN turnover31.6%44.4%42.5%
Administrators who left (past year)0.00.60.5

Weekend nurse staffing is 13% below weekdays (11% statewide). CMS expects about 3.85 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeOhioU.S.
Falls with major injury (long-stay)
F689
4.3%3.1%3.2%
Pressure ulcers (long-stay)
F686
2.3%3.2%4.5%
Antipsychotic medication (long-stay)
F758
11.9%8.5%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.2%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
22.0%25.5%19.5%
Urinary tract infections (long-stay)
F690
0.3%0.4%1.5%
Catheter left in bladder (long-stay)
F690
0.2%0.2%0.7%
New or worse incontinence (long-stay)
F690
26.0%20.9%18.3%
Losing too much weight (long-stay)
F692
10.7%6.1%5.1%
Needing more help with daily activities (long-stay)
F676
7.4%5.0%13.5%
Walking ability got worse (long-stay)
F676
5.7%5.3%12.7%
Depressive symptoms (long-stay)
F740
4.4%31.6%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
19.9%24.4%23.4%
ER visits (short-stay)
F684
11.9%12.6%11.8%

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey5 (Ohio average 5.5)
Repeat fire safety tagsK232 (2 cycles)
Fire safety citations on the last survey
K321
E
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K353
E
Inspect, test, and maintain automatic sprinkler systems.
K511
E
Have properly installed electrical wiring and gas equipment.
K521
E
Ensure heating and ventilation systems that have been properly installed according to the…
K781
E
Have restrictions on the use of portable space heaters.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.