★ OpsStar

Trotwood Health & Rehab LLC: Survey Readiness Report

4911 Covenant House Drive, Dayton, OH 45426 · CCN 365364 · 67 beds · CMS 2★ overall

CMS Special Focus Facility status: SFF Candidate

CMS abuse icon: cited for abuse in the past year or in each of the past 2 years.

Recently surveyed: next standard survey not expected yet
Last standard survey Jun 16, 2026 · 5 months ago · previous Jul 23, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Safe, clean, homelike environment (F921, F584, F919, F908)
    F921 cited in 3 of the last 3 inspection cycles; F584 cited in 2 of the last 3 inspection cycles; F919 cited in 2 of the last 3 inspection cycles
  2. Abuse and neglect (F600, F607)
    F600 cited in 2 of the last 3 inspection cycles; F607 cited in 2 of the last 3 inspection cycles; F600 cited at harm level J (Apr 30, 2026)
  3. Resident rights and dignity (F550, F558, F561)
    F550 cited in 2 of the last 3 inspection cycles; F558 cited in 2 of the last 3 inspection cycles; Complaint citation for F550 in the past 12 months
  4. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; F689 cited at harm level G (Oct 25, 2023)
  5. Pressure ulcers and skin care (F686)
    F686 cited in 2 of the last 3 inspection cycles; F686 cited at harm level G (Nov 7, 2022)

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F727
3 of 3 cycles
Have a registered nurse on duty 8 hours a day; and select a registered nurse to be the director of nurses on a full…
Worst: F · last cited Jun 16, 2026
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited Jun 16, 2026
F921
3 of 3 cycles
Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.
Worst: F · last cited Dec 22, 2025
F657
3 of 3 cycles
Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a…
Worst: E · last cited Jun 16, 2026
F600
2 of 3 cycles
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Worst: J · last cited Apr 30, 2026
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: G · last cited Jul 23, 2024
F686
2 of 3 cycles
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Worst: G · last cited Jun 16, 2026
F584
2 of 3 cycles
Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to…
Worst: F · last cited Aug 22, 2025
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jun 16, 2026
F607
2 of 3 cycles
Develop and implement policies and procedures to prevent abuse, neglect, and theft.
Worst: F · last cited Jun 16, 2026
F868
2 of 3 cycles
Have the Quality Assessment and Assurance group have the required members and meet at least quarterly
Worst: F · last cited Jun 16, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: E · last cited Jun 16, 2026
F755
2 of 3 cycles
Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed…
Worst: D · last cited Jun 11, 2025
F550
2 of 3 cycles
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her…
Worst: D · last cited Jun 16, 2026
F558
2 of 3 cycles
Reasonably accommodate the needs and preferences of each resident.
Worst: D · last cited Jun 16, 2026
F759
2 of 3 cycles
Ensure medication error rates are not 5 percent or greater.
Worst: D · last cited Mar 26, 2025
F919
2 of 3 cycles
Make sure that a working call system is available in each resident's bathroom and bathing area.
Worst: D · last cited Jul 23, 2024
F692
2 of 3 cycles
Provide enough food/fluids to maintain a resident's health.
Worst: D · last cited Jun 16, 2026
F580
2 of 3 cycles
Immediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.)…
Worst: D · last cited Jul 23, 2024

92 health citations across 47 different tags in the last 3 cycles. Last standard survey: 28 citations (Ohio average 10.5).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F600
J
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Immediate jeopardy · Apr 30, 2026 · complaint
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Oct 25, 2023 · complaint
F686
G
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Actual harm · Nov 7, 2022

Complaints and infection control

Complaint citations, past 12 months6
Complaint citations, last 3 cycles52
Infection control (F880) citations, last 3 cycles3

Staffing payroll-based journal (PBJ)

MeasureThis homeOhioU.S.
Total nurse hours per resident per day3.803.713.90
Weekend nurse hours per resident per day3.203.293.43
RN hours per resident per day0.810.640.69
Weekend RN hours per resident per day0.450.430.48
Nursing staff turnover84.3%49.0%45.3%
RN turnover88.9%44.4%42.5%
Administrators who left (past year)n/a0.60.5

Weekend nurse staffing is 16% below weekdays (11% statewide). CMS expects about 4.98 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeOhioU.S.
Falls with major injury (long-stay)
F689
2.8%3.1%3.2%
Pressure ulcers (long-stay)
F686
1.3%3.2%4.5%
Antipsychotic medication (long-stay)
F758
5.1%8.5%15.4%
Anti-anxiety or sleep medication (long-stay)
F758
26.1%25.5%19.5%
Urinary tract infections (long-stay)
F690
0.7%0.4%1.5%
Catheter left in bladder (long-stay)
F690
0.5%0.2%0.7%
New or worse incontinence (long-stay)
F690
8.7%20.9%18.3%
Losing too much weight (long-stay)
F692
3.6%6.1%5.1%
Needing more help with daily activities (long-stay)
F676
1.5%5.0%13.5%
Walking ability got worse (long-stay)
F676
1.6%5.3%12.7%
Depressive symptoms (long-stay)
F740
77.0%31.6%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $53,716
Payment denials, past 3 years1
Fire safety citations, last survey20 (Ohio average 5.5)
Repeat fire safety tagsK291 (3 cycles), K345 (2 cycles), K353 (2 cycles), K521 (2 cycles), K761 (2 cycles), K918 (3 cycles), K222 (2 cycles), K363 (2 cycles), K511 (3 cycles), K741 (3 cycles), K754 (2 cycles), K712 (2 cycles), E004 (2 cycles), K324 (2 cycles), K923 (2 cycles), K372 (2 cycles)
Fire safety citations on the last survey
K291
F
Install emergency lighting that can last at least 1 1/2 hours.
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K521
F
Ensure heating and ventilation systems that have been properly installed according to the…
K761
F
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
K914
F
Ensure receptacles at patient bed locations and where general anesthesia is administered, are…
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K222
E
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K223
E
Provide exit doors that are held open by devices that will automatically close on the activation…
K252
E
Provide at least two remote exits on each floor or fire section of the building.
K293
E
Have properly located and lighted "Exit" signs.
K355
E
Properly select, install, inspect, or maintain portable fire extinguishes.
K363
E
Install corridor and hallway doors that block smoke.
K511
E
Have properly installed electrical wiring and gas equipment.
K741
E
Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where…
K754
E
Provide properly sized and located linen or trash receptacles.
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K712
F
Have simulated fire drills held at unexpected times.
K754
F
Provide properly sized and located linen or trash receptacles.
K781
F
Have restrictions on the use of portable space heaters.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.