★ OpsStar

Hamilton Respiratory and Nursing Center: Survey Readiness Report

2923 Hamilton Mason Road, Hamilton, OH 45011 · CCN 365558 · 80 beds · CMS 3★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Apr 20, 2026 · 7 months ago · previous May 10, 2023
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; Complaint citation for F689 in the past 12 months
  2. Staffing levels and RN coverage (F725)
    4 staffing measures below the state average; Nursing turnover 74.2% vs 49.0% state average
  3. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles
  4. Care plans (F657)
    F657 cited in 2 of the last 3 inspection cycles
  5. Nutrition and weight loss (F692)
    F692 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: E · last cited May 10, 2023
F657
2 of 3 cycles
Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a…
Worst: D · last cited Apr 20, 2026
F692
2 of 3 cycles
Provide enough food/fluids to maintain a resident's health.
Worst: D · last cited Apr 20, 2026
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: D · last cited Feb 23, 2026
F684
2 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: D · last cited May 10, 2023

35 health citations across 29 different tags in the last 3 cycles. Last standard survey: 8 citations (Ohio average 10.5).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months2
Complaint citations, last 3 cycles7
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeOhioU.S.
Total nurse hours per resident per day3.333.713.90
Weekend nurse hours per resident per day3.043.293.43
RN hours per resident per day0.350.640.69
Weekend RN hours per resident per day0.190.430.48
Nursing staff turnover74.2%49.0%45.3%
RN turnover84.6%44.4%42.5%
Administrators who left (past year)0.00.60.5

Weekend nurse staffing is 9% below weekdays (11% statewide). CMS expects about 4.81 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeOhioU.S.
Falls with major injury (long-stay)
F689
0.8%3.1%3.2%
Pressure ulcers (long-stay)
F686
3.2%3.2%4.5%
Antipsychotic medication (long-stay)
F758
8.5%8.5%15.4%
New antipsychotic medication (short-stay)
F758
1.7%1.2%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
36.6%25.5%19.5%
Urinary tract infections (long-stay)
F690
0.4%0.4%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.2%0.7%
New or worse incontinence (long-stay)
F690
13.7%20.9%18.3%
Losing too much weight (long-stay)
F692
7.1%6.1%5.1%
Needing more help with daily activities (long-stay)
F676
3.9%5.0%13.5%
Walking ability got worse (long-stay)
F676
3.9%5.3%12.7%
Depressive symptoms (long-stay)
F740
43.9%31.6%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey6 (Ohio average 5.5)
Repeat fire safety tagsK761 (2 cycles), K351 (2 cycles), K353 (2 cycles), K222 (2 cycles)
Fire safety citations on the last survey
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K363
F
Install corridor and hallway doors that block smoke.
K521
F
Ensure heating and ventilation systems that have been properly installed according to the…
K522
F
Have an externally vented heating system.
K761
F
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
K351
E
Install an approved automatic sprinkler system.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.