★ OpsStar

Pauls Valley Care Center: Survey Readiness Report

1413 South Chickasaw Street, Pauls Valley, OK 73075 · CCN 375463 · 71 beds · CMS 2★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Dec 18, 2025 · 11 months ago · previous Apr 18, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; F689 cited at harm level G (Dec 18, 2025); Complaint citation for F689 in the past 12 months
  2. Psychotropic medications (F758)
    Antipsychotic medication (long-stay): 32.4% vs 17.8% state average; New antipsychotic medication (short-stay): 3.2% vs 1.8% state average; Anti-anxiety or sleep medication (long-stay): 53.8% vs 26.0% state average
  3. Staffing levels and RN coverage (F725)
    2 staffing measures below the state average; Weekend staffing drops 16% vs 10% statewide; Nursing turnover 78.4% vs 55.4% state average
  4. Care plans (F656)
    F656 cited in 2 of the last 3 inspection cycles
  5. Daily living care (ADLs) (F676)
    Needing more help with daily activities (long-stay): 28.4% vs 13.6% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: G · last cited Dec 18, 2025
F656
2 of 3 cycles
Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can…
Worst: E · last cited Dec 18, 2025

15 health citations across 13 different tags in the last 3 cycles. Last standard survey: 5 citations (Oklahoma average 6.5).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Dec 18, 2025 · complaint

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles4
Infection control (F880) citations, last 3 cycles0

Staffing payroll-based journal (PBJ)

MeasureThis homeOklahomaU.S.
Total nurse hours per resident per day2.663.823.90
Weekend nurse hours per resident per day2.233.443.43
RN hours per resident per day0.430.340.69
Weekend RN hours per resident per day0.400.270.48
Nursing staff turnover78.4%55.4%45.3%
RN turnovern/a52.0%42.5%
Administrators who left (past year)0.00.60.5

Weekend nurse staffing is 16% below weekdays (10% statewide). CMS expects about 3.26 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeOklahomaU.S.
Falls with major injury (long-stay)
F689
16.7%4.8%3.2%
Pressure ulcers (long-stay)
F686
4.5%4.7%4.5%
Antipsychotic medication (long-stay)
F758
32.4%17.8%15.4%
New antipsychotic medication (short-stay)
F758
3.2%1.8%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
53.8%26.0%19.5%
Urinary tract infections (long-stay)
F690
0.0%2.7%1.5%
Catheter left in bladder (long-stay)
F690
0.6%1.7%0.7%
New or worse incontinence (long-stay)
F690
18.6%16.4%18.3%
Losing too much weight (long-stay)
F692
0.0%3.2%5.1%
Needing more help with daily activities (long-stay)
F676
28.4%13.6%13.5%
Walking ability got worse (long-stay)
F676
10.3%13.0%12.7%
Depressive symptoms (long-stay)
F740
7.9%3.4%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Hospitalizations per 1,000 long-stay days
F684
2.702.191.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $50,778
Payment denials, past 3 years2
Fire safety citations, last survey8 (Oklahoma average 2.5)
Repeat fire safety tagsK291 (2 cycles), K353 (2 cycles)
Fire safety citations on the last survey
K321
F
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K344
F
Have an alternate power supply for its alarm system.
K362
F
Ensure that corridors are separated from use areas by walls constructed to limit the passage of…
K363
F
Install corridor and hallway doors that block smoke.
K912
F
Have power receptacles that are properly grounded.
K291
E
Install emergency lighting that can last at least 1 1/2 hours.
K293
E
Have properly located and lighted "Exit" signs.
K911
D
Meet requirements for the installation and maintenance of electrical systems.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.