★ OpsStar

Good Shepherd Home Raker Center: Survey Readiness Report

601 St John Street, Allentown, PA 18103 · CCN 395018 · 99 beds · CMS 3★ overall

CMS abuse icon: cited for abuse in the past year or in each of the past 2 years.

Recently surveyed: next standard survey not expected yet
Last standard survey Aug 13, 2026 · 3 months ago · previous Sep 23, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Quality of care (F684)
    F684 cited in 2 of the last 3 inspection cycles; Complaint citation for F684 in the past 12 months
  2. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  3. Abuse and neglect (F600)
    F600 cited at harm level G (Jul 21, 2026); Complaint citation for F600 in the past 12 months
  4. Pressure ulcers and skin care (F686)
    Pressure ulcers (long-stay): 7.1% vs 4.7% state average
  5. Hospital readmissions and discharge planning (F684)
    Hospitalizations per 1,000 long-stay days: 1.88 vs 1.50 state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Aug 13, 2026
F684
2 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: D · last cited Aug 13, 2026

10 health citations across 8 different tags in the last 3 cycles. Last standard survey: 3 citations (Pennsylvania average 10.0).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F600
G
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Actual harm · Jul 21, 2026 · complaint

Complaints and infection control

Complaint citations, past 12 months2
Complaint citations, last 3 cycles2
Infection control (F880) citations, last 3 cycles0

Staffing payroll-based journal (PBJ)

MeasureThis homePennsylvaniaU.S.
Total nurse hours per resident per day5.153.903.90
Weekend nurse hours per resident per day4.363.523.43
RN hours per resident per day1.540.780.69
Weekend RN hours per resident per day1.280.550.48
Nursing staff turnover30.2%44.6%45.3%
RN turnover25.0%39.4%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 15% below weekdays (10% statewide). CMS expects about 5.61 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homePennsylvaniaU.S.
Falls with major injury (long-stay)
F689
0.0%3.1%3.2%
Pressure ulcers (long-stay)
F686
7.1%4.7%4.5%
Antipsychotic medication (long-stay)
F758
14.3%17.6%15.4%
Anti-anxiety or sleep medication (long-stay)
F758
18.5%20.1%19.5%
Urinary tract infections (long-stay)
F690
1.3%1.4%1.5%
Catheter left in bladder (long-stay)
F690
0.4%0.6%0.7%
New or worse incontinence (long-stay)
F690
14.0%25.0%18.3%
Losing too much weight (long-stay)
F692
3.2%6.0%5.1%
Needing more help with daily activities (long-stay)
F676
7.8%16.4%13.5%
Depressive symptoms (long-stay)
F740
0.0%13.8%13.5%
Physically restrained (long-stay)
F604
0.0%0.2%0.1%
Sent back to the hospital (short-stay)
F660
9.1%22.0%23.4%
ER visits (short-stay)
F684
0.0%9.5%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.881.501.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey4 (Pennsylvania average 3.4)
Repeat fire safety tagsK161 (2 cycles), K353 (2 cycles), K321 (2 cycles), K363 (2 cycles)
Fire safety citations on the last survey
K161
E
Use approved construction type or materials.
K353
E
Inspect, test, and maintain automatic sprinkler systems.
K291
C
Install emergency lighting that can last at least 1 1/2 hours.
K918
C
Have generator or other power source capable of supplying service within 10 seconds.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.