★ OpsStar

Saint Mary'S Villa Nursing Hom: Survey Readiness Report

516 St. Mary'S Villa Road, Moscow, PA 18444 · CCN 395104 · 112 beds · CMS 4★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jul 31, 2026 · 3 months ago · previous Sep 12, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Medication use (F755)
    F755 cited in 3 of the last 3 inspection cycles
  2. Bladder care and infections (F690)
    Urinary tract infections (long-stay): 3.1% vs 1.4% state average; New or worse incontinence (long-stay): 33.1% vs 25.0% state average
  3. Nutrition and weight loss (F692)
    Losing too much weight (long-stay): 7.3% vs 6.0% state average
  4. Staffing levels and RN coverage (F725)
    1 staffing measure below the state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F755
3 of 3 cycles
Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed…
Worst: E · last cited Jul 31, 2026

13 health citations across 11 different tags in the last 3 cycles. Last standard survey: 3 citations (Pennsylvania average 10.0).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles1
Infection control (F880) citations, last 3 cycles0

Staffing payroll-based journal (PBJ)

MeasureThis homePennsylvaniaU.S.
Total nurse hours per resident per day4.273.903.90
Weekend nurse hours per resident per day3.743.523.43
RN hours per resident per day0.920.780.69
Weekend RN hours per resident per day0.390.550.48
Nursing staff turnover35.3%44.6%45.3%
RN turnover38.1%39.4%42.5%
Administrators who left (past year)1.00.50.5

Weekend nurse staffing is 12% below weekdays (10% statewide). CMS expects about 3.78 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homePennsylvaniaU.S.
Falls with major injury (long-stay)
F689
2.6%3.1%3.2%
Pressure ulcers (long-stay)
F686
2.0%4.7%4.5%
Antipsychotic medication (long-stay)
F758
15.9%17.6%15.4%
New antipsychotic medication (short-stay)
F758
0.8%1.4%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
20.8%20.1%19.5%
Urinary tract infections (long-stay)
F690
3.1%1.4%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.6%0.7%
New or worse incontinence (long-stay)
F690
33.1%25.0%18.3%
Losing too much weight (long-stay)
F692
7.3%6.0%5.1%
Needing more help with daily activities (long-stay)
F676
10.5%16.4%13.5%
Walking ability got worse (long-stay)
F676
10.0%15.4%12.7%
Depressive symptoms (long-stay)
F740
0.0%13.8%13.5%
Physically restrained (long-stay)
F604
0.0%0.2%0.1%
Sent back to the hospital (short-stay)
F660
19.8%22.0%23.4%
ER visits (short-stay)
F684
7.4%9.5%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.681.501.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey8 (Pennsylvania average 3.4)
Repeat fire safety tagsK211 (2 cycles), K161 (2 cycles), K225 (2 cycles), K321 (3 cycles), K353 (3 cycles), K363 (2 cycles)
Fire safety citations on the last survey
K211
F
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K161
E
Use approved construction type or materials.
K225
E
Have stairways and smokeproof enclosures used as exits that meet safety requirements.
K293
E
Have properly located and lighted "Exit" signs.
K321
E
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K353
E
Inspect, test, and maintain automatic sprinkler systems.
K918
E
Have generator or other power source capable of supplying service within 10 seconds.
K712
D
Have simulated fire drills held at unexpected times.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.