Sunset Ridge Rehabilitation and Nursing Center: Survey Readiness Report

3298 Ridge Road, Bloomsburg, PA 17815 · CCN 395953 · 66 beds · CMS 4★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Jan 23, 2026 · 10 months ago · previous Mar 13, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; Falls with major injury (long-stay): 5.6% vs 3.1% state average
  2. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  3. Quality of care (F684)
    F684 cited in 2 of the last 3 inspection cycles
  4. Medical records (F842)
    F842 cited in 2 of the last 3 inspection cycles
  5. Medication use (F757)
    F757 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: F · last cited Mar 13, 2025
F684
2 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: E · last cited Jan 23, 2026
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: E · last cited Jan 23, 2026
F842
2 of 3 cycles
Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance…
Worst: E · last cited Mar 13, 2025
F757
2 of 3 cycles
Ensure each resident’s drug regimen must be free from unnecessary drugs.
Worst: D · last cited Jan 23, 2026

33 health citations across 28 different tags in the last 3 cycles. Last standard survey: 10 citations (Pennsylvania average 10.0).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F600
G
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Actual harm · Apr 25, 2024

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles0
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homePennsylvaniaU.S.
Total nurse hours per resident per day3.683.903.90
Weekend nurse hours per resident per day3.203.523.43
RN hours per resident per day0.740.780.69
Weekend RN hours per resident per day0.450.550.48
Nursing staff turnover39.7%44.6%45.3%
RN turnover27.3%39.4%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 13% below weekdays (10% statewide). CMS expects about 4.28 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homePennsylvaniaU.S.
Falls with major injury (long-stay)
F689
5.6%3.1%3.2%
Pressure ulcers (long-stay)
F686
0.4%4.7%4.5%
Antipsychotic medication (long-stay)
F758
7.1%17.6%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.4%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
15.0%20.1%19.5%
Urinary tract infections (long-stay)
F690
0.5%1.4%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.6%0.7%
New or worse incontinence (long-stay)
F690
28.1%25.0%18.3%
Losing too much weight (long-stay)
F692
2.0%6.0%5.1%
Needing more help with daily activities (long-stay)
F676
4.3%16.4%13.5%
Walking ability got worse (long-stay)
F676
3.7%15.4%12.7%
Depressive symptoms (long-stay)
F740
18.3%13.8%13.5%
Physically restrained (long-stay)
F604
0.0%0.2%0.1%
Sent back to the hospital (short-stay)
F660
20.8%22.0%23.4%
ER visits (short-stay)
F684
10.0%9.5%11.8%
Hospitalizations per 1,000 long-stay days
F684
2.241.501.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $100,369
Payment denials, past 3 yearsNone
Fire safety citations, last survey3 (Pennsylvania average 3.4)
Repeat fire safety tagsK353 (2 cycles), K363 (2 cycles), K321 (2 cycles)
Fire safety citations on the last survey
K353
E
Inspect, test, and maintain automatic sprinkler systems.
K363
E
Install corridor and hallway doors that block smoke.
K372
E
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.