★ OpsStar

Western Hills Healthcare Residence: Survey Readiness Report

400 Old Sidney Rd, Comanche, TX 76442 · CCN 455602 · 158 beds · CMS 2★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jul 22, 2026 · 4 months ago · previous May 14, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; Falls with major injury (long-stay): 6.9% vs 3.2% state average
  2. Staffing levels and RN coverage (F726, F725)
    F726 cited at harm level K (Mar 25, 2024); 2 staffing measures below the state average
  3. Food safety and kitchen (F812)
    F812 cited in 3 of the last 3 inspection cycles
  4. Care plans (F655)
    F655 cited in 2 of the last 3 inspection cycles
  5. Medication use (F760)
    F760 cited at harm level K (Mar 25, 2024)

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
3 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jul 22, 2026
F655
2 of 3 cycles
Create and put into place a plan for meeting the resident's most immediate needs within 48 hours of being admitted
Worst: E · last cited Jul 22, 2026
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: D · last cited Jul 22, 2026

26 health citations across 22 different tags in the last 3 cycles. Last standard survey: 4 citations (Texas average 9.6).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F760
K
Ensure that residents are free from significant medication errors.
Immediate jeopardy · Mar 25, 2024 · complaint
F726
K
Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that…
Immediate jeopardy · Mar 25, 2024 · complaint
F580
K
Immediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.)…
Immediate jeopardy · Mar 25, 2024 · complaint

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles18
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeTexasU.S.
Total nurse hours per resident per day3.313.423.90
Weekend nurse hours per resident per day3.012.993.43
RN hours per resident per day0.220.440.69
Weekend RN hours per resident per day0.170.350.48
Nursing staff turnover45.5%50.8%45.3%
RN turnovern/a49.8%42.5%
Administrators who left (past year)0.00.60.5

Weekend nurse staffing is 9% below weekdays (12% statewide). CMS expects about 3.33 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeTexasU.S.
Falls with major injury (long-stay)
F689
6.9%3.2%3.2%
Pressure ulcers (long-stay)
F686
2.8%3.7%4.5%
Antipsychotic medication (long-stay)
F758
2.4%9.8%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.4%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
9.6%17.8%19.5%
Urinary tract infections (long-stay)
F690
0.9%0.8%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.3%0.7%
New or worse incontinence (long-stay)
F690
26.4%12.5%18.3%
Losing too much weight (long-stay)
F692
7.2%2.9%5.1%
Needing more help with daily activities (long-stay)
F676
14.4%15.8%13.5%
Walking ability got worse (long-stay)
F676
14.2%12.9%12.7%
Depressive symptoms (long-stay)
F740
0.0%2.3%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Hospitalizations per 1,000 long-stay days
F684
2.152.051.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $62,078
Payment denials, past 3 years1
Fire safety citations, last survey6 (Texas average 3.2)
Repeat fire safety tagsK372 (3 cycles), K321 (3 cycles), K521 (3 cycles)
Fire safety citations on the last survey
K372
F
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
K222
E
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K281
E
Install proper backup exit lighting.
K321
E
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K511
E
Have properly installed electrical wiring and gas equipment.
K521
E
Ensure heating and ventilation systems that have been properly installed according to the…

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.