515 W Ashby Pl, San Antonio, TX 78212 · CCN 455689 · 150 beds · CMS 4★ overall

Past the 15-month federal limit: a survey could come any day
Last standard survey Aug 8, 2025 · 15 months ago · previous Jun 27, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Accidents and falls (F689)
    F689 cited in 2 of the last 3 inspection cycles; F689 cited at harm level G (Jun 27, 2024); F689 cited at harm level J (May 17, 2024)
  2. Infection prevention and control (F880)
    F880 cited in 3 of the last 3 inspection cycles; F880 cited 4 times in the last 3 cycles
  3. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  4. Medical records (F842)
    F842 cited in 2 of the last 3 inspection cycles
  5. Nutrition and weight loss (F692)
    Losing too much weight (long-stay): 5.3% vs 2.9% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Aug 8, 2025
F689
2 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: J · last cited Jun 27, 2024
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Aug 8, 2025
F842
2 of 3 cycles
Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance…
Worst: E · last cited Jul 17, 2025

31 health citations across 23 different tags in the last 3 cycles. Last standard survey: 8 citations (Texas average 9.6).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Jun 27, 2024
F689
J
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Immediate jeopardy · May 17, 2024 · complaint

Complaints and infection control

Complaint citations, past 12 months2
Complaint citations, last 3 cycles14
Infection control (F880) citations, last 3 cycles4

Staffing payroll-based journal (PBJ)

MeasureThis homeTexasU.S.
Total nurse hours per resident per day3.793.423.90
Weekend nurse hours per resident per day3.372.993.43
RN hours per resident per day0.250.440.69
Weekend RN hours per resident per day0.180.350.48
Nursing staff turnover47.3%50.8%45.3%
RN turnover75.0%49.8%42.5%
Administrators who left (past year)1.00.60.5

Weekend nurse staffing is 11% below weekdays (12% statewide). CMS expects about 3.81 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeTexasU.S.
Falls with major injury (long-stay)
F689
2.8%3.2%3.2%
Pressure ulcers (long-stay)
F686
2.4%3.7%4.5%
Antipsychotic medication (long-stay)
F758
5.3%9.8%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.4%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
13.8%17.8%19.5%
Urinary tract infections (long-stay)
F690
0.6%0.8%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.3%0.7%
New or worse incontinence (long-stay)
F690
9.0%12.5%18.3%
Losing too much weight (long-stay)
F692
5.3%2.9%5.1%
Needing more help with daily activities (long-stay)
F676
9.5%15.8%13.5%
Walking ability got worse (long-stay)
F676
21.9%12.9%12.7%
Depressive symptoms (long-stay)
F740
1.6%2.3%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Sent back to the hospital (short-stay)
F660
14.7%25.5%23.4%
ER visits (short-stay)
F684
20.4%12.2%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.422.051.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years2 totaling $24,285
Payment denials, past 3 years1
Fire safety citations, last survey4 (Texas average 3.2)
Repeat fire safety tagsK311 (2 cycles), K923 (2 cycles), K211 (2 cycles), K741 (2 cycles)
Fire safety citations on the last survey
K352
F
Properly install and monitor supervisory attachments on automatic sprinkler systems.
K372
F
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
K311
E
Have an enclosure around a vertical opening shaft.
K353
E
Inspect, test, and maintain automatic sprinkler systems.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.