★ OpsStar

Parks Health Center: Survey Readiness Report

111 Parks Village Dr., Odessa, TX 79765 · CCN 455690 · 90 beds · CMS 3★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Jan 15, 2026 · 10 months ago · previous Oct 17, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Medication use (F755)
    F755 cited in 3 of the last 3 inspection cycles
  2. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles
  3. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  4. Care plans (F656)
    F656 cited in 2 of the last 3 inspection cycles
  5. Accidents and falls (F689)
    F689 cited at harm level G (Aug 27, 2026); Complaint citation for F689 in the past 12 months

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F755
3 of 3 cycles
Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed…
Worst: E · last cited Jan 15, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: E · last cited Jan 15, 2026
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: E · last cited Jan 15, 2026
F656
2 of 3 cycles
Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can…
Worst: D · last cited Jan 15, 2026

16 health citations across 11 different tags in the last 3 cycles. Last standard survey: 7 citations (Texas average 9.6).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Aug 27, 2026 · complaint

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles7
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeTexasU.S.
Total nurse hours per resident per day3.503.423.90
Weekend nurse hours per resident per day3.132.993.43
RN hours per resident per day0.630.440.69
Weekend RN hours per resident per day0.530.350.48
Nursing staff turnover54.7%50.8%45.3%
RN turnover80.0%49.8%42.5%
Administrators who left (past year)1.00.60.5

Weekend nurse staffing is 11% below weekdays (12% statewide). CMS expects about 3.82 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeTexasU.S.
Falls with major injury (long-stay)
F689
1.1%3.2%3.2%
Pressure ulcers (long-stay)
F686
15.3%3.7%4.5%
Antipsychotic medication (long-stay)
F758
5.5%9.8%15.4%
New antipsychotic medication (short-stay)
F758
0.4%1.4%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
32.0%17.8%19.5%
Urinary tract infections (long-stay)
F690
1.7%0.8%1.5%
Catheter left in bladder (long-stay)
F690
0.7%0.3%0.7%
New or worse incontinence (long-stay)
F690
15.7%12.5%18.3%
Losing too much weight (long-stay)
F692
13.9%2.9%5.1%
Needing more help with daily activities (long-stay)
F676
11.7%15.8%13.5%
Walking ability got worse (long-stay)
F676
23.5%12.9%12.7%
Depressive symptoms (long-stay)
F740
0.0%2.3%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Sent back to the hospital (short-stay)
F660
23.1%25.5%23.4%
ER visits (short-stay)
F684
15.0%12.2%11.8%
Hospitalizations per 1,000 long-stay days
F684
2.242.051.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $13,065
Payment denials, past 3 yearsNone
Fire safety citations, last survey4 (Texas average 3.2)
Repeat fire safety tagsK918 (2 cycles), K372 (2 cycles), K521 (3 cycles)
Fire safety citations on the last survey
K918
F
Have generator or other power source capable of supplying service within 10 seconds.
K372
E
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
K741
E
Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where…
K521
C
Ensure heating and ventilation systems that have been properly installed according to the…

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.