★ OpsStar

Puget Sound Care: Survey Readiness Report

4001 Capitol Mall Dr Southwest, Olympia, WA 98502 · CCN 505299 · 108 beds · CMS 4★ overall

Window opens soon: surveys can start at 9 months
Last standard survey Jan 23, 2026 · 10 months ago · previous Nov 7, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Quality of care (F684)
    F684 cited in 3 of the last 3 inspection cycles
  2. Staffing levels and RN coverage (F725)
    4 staffing measures below the state average; Nursing turnover 53.4% vs 43.9% state average
  3. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  4. Care plans (F656)
    F656 cited in 2 of the last 3 inspection cycles
  5. Medication storage and labeling (F761)
    F761 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F684
3 of 3 cycles
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Worst: E · last cited Jan 23, 2026
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Jul 1, 2025
F656
2 of 3 cycles
Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can…
Worst: D · last cited Jan 23, 2026
F761
2 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: D · last cited Jan 23, 2026

21 health citations across 15 different tags in the last 3 cycles. Last standard survey: 9 citations (Washington average 15.7).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F760
G
Ensure that residents are free from significant medication errors.
Actual harm · Mar 28, 2024 · complaint

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles3
Infection control (F880) citations, last 3 cycles1

Staffing payroll-based journal (PBJ)

MeasureThis homeWashingtonU.S.
Total nurse hours per resident per day4.104.423.90
Weekend nurse hours per resident per day3.363.823.43
RN hours per resident per day0.440.990.69
Weekend RN hours per resident per day0.250.710.48
Nursing staff turnover53.4%43.9%45.3%
RN turnover33.3%43.8%42.5%
Administrators who left (past year)1.00.50.5

Weekend nurse staffing is 18% below weekdays (14% statewide). CMS expects about 3.66 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeWashingtonU.S.
Falls with major injury (long-stay)
F689
3.8%2.6%3.2%
Pressure ulcers (long-stay)
F686
7.8%4.4%4.5%
Antipsychotic medication (long-stay)
F758
11.3%15.0%15.4%
New antipsychotic medication (short-stay)
F758
0.6%1.3%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
6.5%12.5%19.5%
Urinary tract infections (long-stay)
F690
2.5%1.7%1.5%
Catheter left in bladder (long-stay)
F690
0.3%0.8%0.7%
New or worse incontinence (long-stay)
F690
18.1%21.6%18.3%
Losing too much weight (long-stay)
F692
11.5%5.6%5.1%
Needing more help with daily activities (long-stay)
F676
10.1%13.8%13.5%
Walking ability got worse (long-stay)
F676
8.4%15.6%12.7%
Depressive symptoms (long-stay)
F740
6.8%17.9%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
17.4%19.7%23.4%
ER visits (short-stay)
F684
13.5%13.0%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.081.261.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $8,018
Payment denials, past 3 yearsNone
Fire safety citations, last survey4 (Washington average 9.7)
Repeat fire safety tagsK353 (2 cycles), K372 (2 cycles)
Fire safety citations on the last survey
K374
E
Install smoke barrier doors that can resist smoke for at least 20 minutes.
K324
D
Provide properly protected cooking facilities.
K353
D
Inspect, test, and maintain automatic sprinkler systems.
K372
D
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.