★ OpsStar

Evergreen Health Services: Survey Readiness Report

1250 Evergreen St, Shawano, WI 54166 · CCN 525343 · 50 beds · CMS 3★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jul 29, 2026 · 4 months ago · previous May 29, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Pressure ulcers and skin care (F686)
    F686 cited in 2 of the last 3 inspection cycles; F686 cited at harm level G (Jul 29, 2026); Pressure ulcers (long-stay): 6.7% vs 4.9% state average
  2. Accidents and falls (F689)
    F689 cited at harm level J (Sep 16, 2025); F689 cited at harm level G (Mar 19, 2025); Falls with major injury (long-stay): 4.7% vs 3.3% state average
  3. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 3 times in the last 3 cycles
  4. Staffing levels and RN coverage (F725)
    4 staffing measures below the state average; Nursing turnover 54.5% vs 46.7% state average
  5. Medication use (F755)
    F755 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F686
2 of 3 cycles
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Worst: G · last cited Jul 29, 2026
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Jul 29, 2026
F755
2 of 3 cycles
Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed…
Worst: D · last cited May 29, 2025

23 health citations across 18 different tags in the last 3 cycles. Last standard survey: 5 citations (Wisconsin average 9.4).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F686
G
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Actual harm · Jul 29, 2026
F689
J
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Immediate jeopardy · Sep 16, 2025 · complaint
F689
G
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Actual harm · Mar 19, 2025 · complaint

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles9
Infection control (F880) citations, last 3 cycles3

Staffing payroll-based journal (PBJ)

MeasureThis homeWisconsinU.S.
Total nurse hours per resident per day3.474.253.90
Weekend nurse hours per resident per day3.013.753.43
RN hours per resident per day0.670.980.69
Weekend RN hours per resident per day0.360.660.48
Nursing staff turnover54.5%46.7%45.3%
RN turnover44.4%40.1%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 13% below weekdays (12% statewide). CMS expects about 3.84 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeWisconsinU.S.
Falls with major injury (long-stay)
F689
4.7%3.3%3.2%
Pressure ulcers (long-stay)
F686
6.7%4.9%4.5%
Antipsychotic medication (long-stay)
F758
7.2%15.9%15.4%
New antipsychotic medication (short-stay)
F758
2.1%1.2%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
5.3%16.8%19.5%
Urinary tract infections (long-stay)
F690
3.1%2.7%1.5%
Catheter left in bladder (long-stay)
F690
1.9%1.9%0.7%
New or worse incontinence (long-stay)
F690
28.4%23.6%18.3%
Losing too much weight (long-stay)
F692
4.4%4.9%5.1%
Needing more help with daily activities (long-stay)
F676
15.9%15.8%13.5%
Walking ability got worse (long-stay)
F676
32.2%17.0%12.7%
Depressive symptoms (long-stay)
F740
3.2%6.0%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $14,020
Payment denials, past 3 yearsNone
Fire safety citations, last survey3 (Wisconsin average 5.5)
Repeat fire safety tagsK353 (2 cycles)
Fire safety citations on the last survey
K223
F
Provide exit doors that are held open by devices that will automatically close on the activation…
K353
F
Inspect, test, and maintain automatic sprinkler systems.
K918
F
Have generator or other power source capable of supplying service within 10 seconds.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.