★ OpsStar

Morrow Memorial Home: Survey Readiness Report

331 S. Water St., Sparta, WI 54656 · CCN 525662 · 78 beds · CMS 5★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jul 21, 2026 · 4 months ago · previous Jun 4, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  2. Daily living care (ADLs) (F676)
    Needing more help with daily activities (long-stay): 21.1% vs 15.8% state average; Walking ability got worse (long-stay): 24.9% vs 17.0% state average
  3. Resident rights and dignity (F550)
    F550 cited in 2 of the last 3 inspection cycles
  4. Accidents and falls (F689)
    Falls with major injury (long-stay): 8.6% vs 3.3% state average
  5. Hospital readmissions and discharge planning (F660, F684)
    Sent back to the hospital (short-stay): 29.3% vs 22.5% state average; ER visits (short-stay): 19.0% vs 15.6% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F550
2 of 3 cycles
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her…
Worst: D · last cited Jun 4, 2025
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: D · last cited Jun 4, 2025

9 health citations across 7 different tags in the last 3 cycles. Last standard survey: 0 citations (Wisconsin average 9.4).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F580
G
Immediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.)…
Actual harm · Mar 28, 2024

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles0
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeWisconsinU.S.
Total nurse hours per resident per day4.144.253.90
Weekend nurse hours per resident per day3.683.753.43
RN hours per resident per day0.900.980.69
Weekend RN hours per resident per day0.610.660.48
Nursing staff turnover35.1%46.7%45.3%
RN turnover27.8%40.1%42.5%
Administrators who left (past year)0.00.50.5

Weekend nurse staffing is 11% below weekdays (12% statewide). CMS expects about 3.28 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeWisconsinU.S.
Falls with major injury (long-stay)
F689
8.6%3.3%3.2%
Pressure ulcers (long-stay)
F686
4.0%4.9%4.5%
Antipsychotic medication (long-stay)
F758
17.1%15.9%15.4%
New antipsychotic medication (short-stay)
F758
0.9%1.2%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
20.0%16.8%19.5%
Urinary tract infections (long-stay)
F690
0.5%2.7%1.5%
Catheter left in bladder (long-stay)
F690
1.8%1.9%0.7%
New or worse incontinence (long-stay)
F690
18.9%23.6%18.3%
Losing too much weight (long-stay)
F692
4.6%4.9%5.1%
Needing more help with daily activities (long-stay)
F676
21.1%15.8%13.5%
Walking ability got worse (long-stay)
F676
24.9%17.0%12.7%
Depressive symptoms (long-stay)
F740
4.8%6.0%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
29.3%22.5%23.4%
ER visits (short-stay)
F684
19.0%15.6%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.581.571.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey6 (Wisconsin average 5.5)
Repeat fire safety tagsK353 (2 cycles)
Fire safety citations on the last survey
K345
F
Have approved installation, maintenance and testing program for fire alarm systems.
K222
E
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K914
E
Ensure receptacles at patient bed locations and where general anesthesia is administered, are…
K351
D
Install an approved automatic sprinkler system.
K353
D
Inspect, test, and maintain automatic sprinkler systems.
K912
D
Have power receptacles that are properly grounded.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.