★ OpsStar

Crook County Medical Services District Long Term C: Survey Readiness Report

713 Oak St, Sundance, WY 82729 · CCN 535029 · 32 beds · CMS 3★ overall

Past the 15-month federal limit: a survey could come any day
Last standard survey Aug 14, 2025 · 15 months ago · previous May 9, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Staffing levels and RN coverage (F727, F732, F725)
    F727 cited in 2 of the last 3 inspection cycles; F732 cited in 2 of the last 3 inspection cycles; Nursing turnover 75.0% vs 52.1% state average
  2. Infection prevention and control (F880)
    F880 cited in 3 of the last 3 inspection cycles; F880 cited 3 times in the last 3 cycles
  3. Abuse and neglect (F609, F600)
    F609 cited in 2 of the last 3 inspection cycles; F600 cited at harm level G (Sep 5, 2024)
  4. Bladder care and infections (F690)
    Urinary tract infections (long-stay): 7.2% vs 3.0% state average; New or worse incontinence (long-stay): 29.8% vs 21.4% state average
  5. Administration (F851)
    F851 cited in 2 of the last 3 inspection cycles

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Aug 14, 2025
F727
2 of 3 cycles
Have a registered nurse on duty 8 hours a day; and select a registered nurse to be the director of nurses on a full…
Worst: F · last cited Aug 14, 2025
F851
2 of 3 cycles
Electronically submit to CMS complete and accurate direct care staffing information, based on payroll and other…
Worst: F · last cited May 9, 2024
F609
2 of 3 cycles
Timely report suspected abuse, neglect, or theft and report the results of the investigation to proper authorities.
Worst: D · last cited Nov 5, 2024
F641
2 of 3 cycles
Ensure each resident receives an accurate assessment.
Worst: D · last cited May 9, 2024
F732
2 of 3 cycles
Post nurse staffing information every day.
Worst: C · last cited May 9, 2024

25 health citations across 18 different tags in the last 3 cycles. Last standard survey: 3 citations (Wyoming average 7.9).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F600
G
Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect…
Actual harm · Sep 5, 2024 · complaint

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles3
Infection control (F880) citations, last 3 cycles3

Staffing payroll-based journal (PBJ)

MeasureThis homeWyomingU.S.
Total nurse hours per resident per day4.803.983.90
Weekend nurse hours per resident per day4.023.383.43
RN hours per resident per day1.000.960.69
Weekend RN hours per resident per day0.620.640.48
Nursing staff turnover75.0%52.1%45.3%
RN turnover55.6%44.8%42.5%
Administrators who left (past year)n/a0.60.5

Weekend nurse staffing is 16% below weekdays (15% statewide). CMS expects about 3.46 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeWyomingU.S.
Falls with major injury (long-stay)
F689
6.3%5.0%3.2%
Pressure ulcers (long-stay)
F686
8.2%4.5%4.5%
Antipsychotic medication (long-stay)
F758
19.4%21.4%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.6%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
8.7%15.3%19.5%
Urinary tract infections (long-stay)
F690
7.2%3.0%1.5%
Catheter left in bladder (long-stay)
F690
0.6%1.4%0.7%
New or worse incontinence (long-stay)
F690
29.8%21.4%18.3%
Losing too much weight (long-stay)
F692
13.5%5.6%5.1%
Needing more help with daily activities (long-stay)
F676
16.8%17.2%13.5%
Walking ability got worse (long-stay)
F676
14.7%14.4%12.7%
Depressive symptoms (long-stay)
F740
3.8%6.9%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Hospitalizations per 1,000 long-stay days
F684
1.571.331.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $8,981
Payment denials, past 3 yearsNone
Fire safety citations, last survey11 (Wyoming average 6.5)
Repeat fire safety tagsK345 (2 cycles)
Fire safety citations on the last survey
E026
F
Establish roles under a Waiver declared by secretary.
E031
F
Provide emergency officials' contact information.
E037
F
Establish staff and initial training requirements.
E041
F
Implement emergency and standby power systems.
K353
E
Inspect, test, and maintain automatic sprinkler systems.
K751
E
Have restrictions on the use of flammable curtains.
K918
E
Have generator or other power source capable of supplying service within 10 seconds.
K100
D
Meet other general requirements.
K222
D
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K223
D
Provide exit doors that are held open by devices that will automatically close on the activation…
K324
D
Provide properly protected cooking facilities.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.