★ OpsStar

Sage View Care Center: Survey Readiness Report

1325 Sage St, Rock Springs, WY 82901 · CCN 535056 · 82 beds · CMS 3★ overall

Past the 15-month federal limit: a survey could come any day
Last standard survey Feb 13, 2025 · 21 months ago · previous Nov 16, 2023
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  2. Food safety and kitchen (F805)
    F805 cited at harm level G (Jan 15, 2026); Complaint citation for F805 in the past 12 months
  3. Bladder care and infections (F690)
    Catheter left in bladder (long-stay): 4.6% vs 1.4% state average
  4. Staffing levels and RN coverage (F725)
    4 staffing measures below the state average
  5. Daily living care (ADLs) (F676)
    Walking ability got worse (long-stay): 25.6% vs 14.4% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Feb 21, 2024

12 health citations across 11 different tags in the last 3 cycles. Last standard survey: 3 citations (Wyoming average 7.9).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F805
G
Ensure each resident receives and the facility provides food prepared in a form designed to meet individual needs.
Actual harm · Jan 15, 2026 · complaint

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles4
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeWyomingU.S.
Total nurse hours per resident per day3.383.983.90
Weekend nurse hours per resident per day2.823.383.43
RN hours per resident per day0.860.960.69
Weekend RN hours per resident per day0.310.640.48
Nursing staff turnover54.4%52.1%45.3%
RN turnover12.5%44.8%42.5%
Administrators who left (past year)0.00.60.5

Weekend nurse staffing is 16% below weekdays (15% statewide). CMS expects about 3.96 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeWyomingU.S.
Falls with major injury (long-stay)
F689
3.0%5.0%3.2%
Pressure ulcers (long-stay)
F686
4.6%4.5%4.5%
Antipsychotic medication (long-stay)
F758
28.8%21.4%15.4%
New antipsychotic medication (short-stay)
F758
1.5%1.6%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
7.4%15.3%19.5%
Urinary tract infections (long-stay)
F690
1.9%3.0%1.5%
Catheter left in bladder (long-stay)
F690
4.6%1.4%0.7%
New or worse incontinence (long-stay)
F690
25.0%21.4%18.3%
Losing too much weight (long-stay)
F692
2.0%5.6%5.1%
Needing more help with daily activities (long-stay)
F676
18.8%17.2%13.5%
Walking ability got worse (long-stay)
F676
25.6%14.4%12.7%
Depressive symptoms (long-stay)
F740
3.8%6.9%13.5%
Physically restrained (long-stay)
F604
0.0%0.1%0.1%
Sent back to the hospital (short-stay)
F660
10.3%17.3%23.4%
ER visits (short-stay)
F684
15.5%15.9%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.061.331.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $8,278
Payment denials, past 3 yearsNone
Fire safety citations, last survey5 (Wyoming average 6.5)
Repeat fire safety tagsK351 (2 cycles), K222 (2 cycles), K345 (2 cycles), K321 (2 cycles)
Fire safety citations on the last survey
K351
F
Install an approved automatic sprinkler system.
K222
E
Add doors in an exit area that do not require the use of a key from the exit side unless in case…
K712
E
Have simulated fire drills held at unexpected times.
K200
D
Meet other general requirements.
K372
D
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.