★ OpsStar

Belmont Healthcare Center: Survey Readiness Report

2140 Carlmont Drive, Belmont, CA 94002 · CCN 555657 · 74 beds · CMS 5★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jun 22, 2026 · 5 months ago · previous Dec 5, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Infection prevention and control (F880)
    F880 cited in 2 of the last 3 inspection cycles; F880 cited 2 times in the last 3 cycles
  2. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  3. Staffing levels and RN coverage (F725)
    3 staffing measures below the state average
  4. Bladder care and infections (F690)
    New or worse incontinence (long-stay): 15.2% vs 9.8% state average
  5. Notifying doctors and families (F580)
    Complaint citation for F580 in the past 12 months

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: E · last cited Jun 22, 2026
F880
2 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: D · last cited Dec 5, 2024

21 health citations across 18 different tags in the last 3 cycles. Last standard survey: 2 citations (California average 15.7).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months1
Complaint citations, last 3 cycles6
Infection control (F880) citations, last 3 cycles2

Staffing payroll-based journal (PBJ)

MeasureThis homeCaliforniaU.S.
Total nurse hours per resident per day4.004.543.90
Weekend nurse hours per resident per day3.624.103.43
RN hours per resident per day0.640.680.69
Weekend RN hours per resident per day0.560.520.48
Nursing staff turnover28.0%36.6%45.3%
RN turnover22.2%37.8%42.5%
Administrators who left (past year)1.00.40.5

Weekend nurse staffing is 10% below weekdays (10% statewide). CMS expects about 4.68 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeCaliforniaU.S.
Falls with major injury (long-stay)
F689
0.7%1.6%3.2%
Pressure ulcers (long-stay)
F686
0.0%4.3%4.5%
Antipsychotic medication (long-stay)
F758
0.9%12.3%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.3%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
6.5%13.7%19.5%
Urinary tract infections (long-stay)
F690
0.0%1.2%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.7%0.7%
New or worse incontinence (long-stay)
F690
15.2%9.8%18.3%
Losing too much weight (long-stay)
F692
4.1%4.1%5.1%
Needing more help with daily activities (long-stay)
F676
0.0%10.2%13.5%
Walking ability got worse (long-stay)
F676
7.0%8.9%12.7%
Depressive symptoms (long-stay)
F740
2.3%7.6%13.5%
Physically restrained (long-stay)
F604
0.0%0.3%0.1%
Sent back to the hospital (short-stay)
F660
22.3%22.6%23.4%
ER visits (short-stay)
F684
12.7%11.1%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.932.211.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey6 (California average 6.3)
Repeat fire safety tagsK363 (2 cycles), K919 (3 cycles), K923 (2 cycles), E032 (2 cycles), K712 (2 cycles), K353 (2 cycles), K918 (2 cycles)
Fire safety citations on the last survey
K711
F
Provide a written emergency evacuation plan.
K363
E
Install corridor and hallway doors that block smoke.
K919
D
Meet requirements for the use of electrical equipment.
K923
D
Have proper medical gas storage and administration areas.
E032
C
Provide primary/alternate means for communication.
K712
C
Have simulated fire drills held at unexpected times.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.