★ OpsStar

Park View Nursing and Subacute: Survey Readiness Report

6740 Wilbur Ave Opco, LLC, Reseda, CA 91335 · CCN 555716 · 99 beds · CMS 2★ overall

Recently surveyed: next standard survey not expected yet
Last standard survey Jun 4, 2026 · 5 months ago · previous May 23, 2025
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Resident rights and dignity (F558, F550, F585)
    F558 cited in 2 of the last 3 inspection cycles; F550 cited in 2 of the last 3 inspection cycles; Complaint citation for F585 in the past 12 months
  2. Pressure ulcers and skin care (F686)
    F686 cited in 2 of the last 3 inspection cycles; Complaint citation for F686 in the past 12 months; Pressure ulcers (long-stay): 9.8% vs 4.3% state average
  3. Quality of care (F658, F698, F688)
    F658 cited in 2 of the last 3 inspection cycles; F698 cited in 2 of the last 3 inspection cycles; Complaint citation for F688 in the past 12 months
  4. Infection prevention and control (F880)
    F880 cited in 3 of the last 3 inspection cycles; F880 cited 5 times in the last 3 cycles
  5. Care plans (F656, F655)
    F656 cited in 3 of the last 3 inspection cycles; Complaint citation for F655 in the past 12 months

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F656
3 of 3 cycles
Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can…
Worst: E · last cited Jun 4, 2026
F689
3 of 3 cycles
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Worst: E · last cited Jun 4, 2026
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Jun 4, 2026
F755
3 of 3 cycles
Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed…
Worst: E · last cited Jun 4, 2026
F761
3 of 3 cycles
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional…
Worst: E · last cited Jun 4, 2026
F842
3 of 3 cycles
Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance…
Worst: E · last cited Jun 4, 2026
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: E · last cited Jun 4, 2026
F686
2 of 3 cycles
Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Worst: E · last cited Jun 4, 2026
F690
2 of 3 cycles
Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care,…
Worst: E · last cited Jun 4, 2026
F695
2 of 3 cycles
Provide safe and appropriate respiratory care for a resident when needed.
Worst: E · last cited Jun 4, 2026
F558
2 of 3 cycles
Reasonably accommodate the needs and preferences of each resident.
Worst: E · last cited Jan 30, 2026
F550
2 of 3 cycles
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her…
Worst: D · last cited Jun 4, 2026
F584
2 of 3 cycles
Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to…
Worst: D · last cited Jun 4, 2026
F658
2 of 3 cycles
Ensure services provided by the nursing facility meet professional standards of quality.
Worst: D · last cited Jun 4, 2026
F698
2 of 3 cycles
Provide safe, appropriate dialysis care/services for a resident who requires such services.
Worst: D · last cited Jun 4, 2026

75 health citations across 39 different tags in the last 3 cycles. Last standard survey: 28 citations (California average 15.7).

Harm-level citations severity G to L, past 3 cycles

None.

Complaints and infection control

Complaint citations, past 12 months7
Complaint citations, last 3 cycles28
Infection control (F880) citations, last 3 cycles5

Staffing payroll-based journal (PBJ)

MeasureThis homeCaliforniaU.S.
Total nurse hours per resident per day4.684.543.90
Weekend nurse hours per resident per day4.404.103.43
RN hours per resident per day0.670.680.69
Weekend RN hours per resident per day0.770.520.48
Nursing staff turnover20.8%36.6%45.3%
RN turnover10.0%37.8%42.5%
Administrators who left (past year)0.00.40.5

Weekend nurse staffing is 6% below weekdays (10% statewide). CMS expects about 5.86 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeCaliforniaU.S.
Falls with major injury (long-stay)
F689
0.0%1.6%3.2%
Pressure ulcers (long-stay)
F686
9.8%4.3%4.5%
Antipsychotic medication (long-stay)
F758
11.7%12.3%15.4%
New antipsychotic medication (short-stay)
F758
1.4%1.3%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
9.3%13.7%19.5%
Urinary tract infections (long-stay)
F690
0.3%1.2%1.5%
Catheter left in bladder (long-stay)
F690
0.1%0.7%0.7%
New or worse incontinence (long-stay)
F690
3.9%9.8%18.3%
Losing too much weight (long-stay)
F692
2.5%4.1%5.1%
Needing more help with daily activities (long-stay)
F676
10.1%10.2%13.5%
Walking ability got worse (long-stay)
F676
3.4%8.9%12.7%
Depressive symptoms (long-stay)
F740
3.6%7.6%13.5%
Physically restrained (long-stay)
F604
0.3%0.3%0.1%
Sent back to the hospital (short-stay)
F660
25.2%22.6%23.4%
ER visits (short-stay)
F684
2.8%11.1%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.382.211.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 yearsNone
Payment denials, past 3 yearsNone
Fire safety citations, last survey2 (California average 6.3)
Repeat fire safety tagsK351 (2 cycles), K712 (2 cycles), K353 (2 cycles), K511 (2 cycles)
Fire safety citations on the last survey
K351
F
Install an approved automatic sprinkler system.
K712
E
Have simulated fire drills held at unexpected times.

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.