★ OpsStar

Brady West Rehab & Nursing: Survey Readiness Report

2201 Menard Hwy, Brady, TX 76825 · CCN 676034 · 106 beds · CMS 5★ overall

In the survey window: likely within the next 3 months
Last standard survey Sep 4, 2025 · 14 months ago · previous Aug 22, 2024
Facility profileCompare with nearby homes
In plain English Good questions to ask on a tour

Where surveyors will likely look

  1. Infection prevention and control (F880)
    F880 cited in 3 of the last 3 inspection cycles; F880 cited 3 times in the last 3 cycles
  2. Food safety and kitchen (F812)
    F812 cited in 2 of the last 3 inspection cycles
  3. Resident rights and dignity (F552)
    F552 cited in 2 of the last 3 inspection cycles
  4. Medication use (F755)
    F755 cited in 2 of the last 3 inspection cycles
  5. Hospital readmissions and discharge planning (F684)
    ER visits (short-stay): 24.3% vs 12.2% state average

Repeat citations tags cited in 2 or more of the last 3 inspection cycles

TagRequirement
F880
3 of 3 cycles
Provide and implement an infection prevention and control program.
Worst: E · last cited Sep 4, 2025
F812
2 of 3 cycles
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in…
Worst: F · last cited Sep 4, 2025
F552
2 of 3 cycles
Ensure that residents are fully informed and understand their health status, care and treatments.
Worst: E · last cited Aug 22, 2024
F755
2 of 3 cycles
Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed…
Worst: E · last cited Aug 22, 2024

23 health citations across 18 different tags in the last 3 cycles. Last standard survey: 3 citations (Texas average 9.6).

Harm-level citations severity G to L, past 3 cycles

TagRequirement
F790
G
Provide routine and 24-hour emergency dental care for each resident.
Actual harm · Aug 22, 2024

Complaints and infection control

Complaint citations, past 12 months0
Complaint citations, last 3 cycles11
Infection control (F880) citations, last 3 cycles3

Staffing payroll-based journal (PBJ)

MeasureThis homeTexasU.S.
Total nurse hours per resident per day3.503.423.90
Weekend nurse hours per resident per day3.082.993.43
RN hours per resident per day0.480.440.69
Weekend RN hours per resident per day0.440.350.48
Nursing staff turnover48.8%50.8%45.3%
RN turnover57.1%49.8%42.5%
Administrators who left (past year)2.00.60.5

Weekend nurse staffing is 12% below weekdays (12% statewide). CMS expects about 3.29 nurse hours per resident per day for this home's resident needs.

Quality measures lower is better

MeasureThis homeTexasU.S.
Falls with major injury (long-stay)
F689
4.8%3.2%3.2%
Pressure ulcers (long-stay)
F686
2.2%3.7%4.5%
Antipsychotic medication (long-stay)
F758
6.0%9.8%15.4%
New antipsychotic medication (short-stay)
F758
0.0%1.4%1.5%
Anti-anxiety or sleep medication (long-stay)
F758
18.4%17.8%19.5%
Urinary tract infections (long-stay)
F690
0.0%0.8%1.5%
Catheter left in bladder (long-stay)
F690
0.0%0.3%0.7%
New or worse incontinence (long-stay)
F690
5.4%12.5%18.3%
Losing too much weight (long-stay)
F692
3.2%2.9%5.1%
Needing more help with daily activities (long-stay)
F676
10.3%15.8%13.5%
Walking ability got worse (long-stay)
F676
1.1%12.9%12.7%
Depressive symptoms (long-stay)
F740
0.0%2.3%13.5%
Physically restrained (long-stay)
F604
0.0%0.0%0.1%
Sent back to the hospital (short-stay)
F660
13.3%25.5%23.4%
ER visits (short-stay)
F684
24.3%12.2%11.8%
Hospitalizations per 1,000 long-stay days
F684
1.732.051.81

Highlighted rows are at least 20% worse than the state average. The F-tag under each measure is the requirement surveyors usually review for it.

Penalties and fire safety

Federal fines, past 3 years1 totaling $10,527
Payment denials, past 3 yearsNone
Fire safety citations, last survey6 (Texas average 3.2)
Repeat fire safety tagsK321 (2 cycles), K211 (3 cycles), K521 (3 cycles)
Fire safety citations on the last survey
E039
F
Conduct testing and exercise requirements.
K321
E
Ensure that special areas are constructed so that walls can resist fire for one hour or have an…
K511
E
Have properly installed electrical wiring and gas equipment.
K920
E
Ensure proper usage of power strips and extension cords.
K211
C
Keep aisles, corridors, and exits free of obstruction in case of emergency.
K521
C
Ensure heating and ventilation systems that have been properly installed according to the…

This is not the official CMS CASPER or iQIES pre-survey report, which only the facility and surveyors can see. It is built by OpsStar from public CMS Provider Data Catalog data (updated Oct 1, 2026): health and fire safety deficiencies, penalties, payroll-based staffing and quality measures. Surveyors also use complaint intake, facility-reported incidents and their own observations, which are not public. Administrators can pull their facility's own CASPER reports in iQIES.